calorique embedded melting system Benutzerhandbuch

Seite von 8
Components
Calorique heating mats. Supplied by Calorique or authorized
distributor. See the following section for specifications of heat-
ing mats.
Electrical control device. Supplied by Calorique, automati-
cally turns the system on and off based on the temperature,
humidity, and presence of precipitation. This unit is a double-
pole line voltage unit that meets National Electrical code
requirements.
Overcurrent Protection. User / installer supplied. The circuit
breaker used with this sistem must have an overcurrent rating
of 30 amps and an integral GFCI rated for 30mA equipment
protection.
Wiring and conduit. User / installer supplied. As required by
national and local code for outdoor installation.
Junction boxes certified for use in outdoor, buried applica-
tions.
Insulation 
(rigid foam or radiant barrier)
User / installer supplied.
When using rigid foam, the insulation must have the following
properties:
Walkways: one inch (2.5 cm) or thicker with a minimum
strength of 25 psi.
Driveways and other vehicular traffic areas: two inches (5.0
cm) or thicker with a minimum strength of 60 psi.s
Warning labels. Supplied by Calorique or authorized distribu-
tor. 
Element Labels. Mounted on the non-heating leads. Both
labels must remain in place as they supply necessary infor-
mation about the elements. If the leads are cut to length,
the trimmed-off label must be reattached within two inches
(5.0 cm) of the end of the cable.
Junction Box Label. Must be attached to the junction box.
Stakes. Supplied by Calorique or authorized distributor.
Warrantee Card. This card must be filled out and returned to
Calorique to ensure proper registration of the warrantee.
Specification Sheet. Provides specifications for all heating
elements included with the system.