calorique embedded melting system Benutzerhandbuch

Seite von 8
Installation
1. Using an accurate ohm meter, test each element to ensure
that it is within the limits shown on the specification sheet.
2. Grade area to be heated as normal. Remember to grade down
an extra amount equal to the thickness of the insulating mate-
rial used.
3. Lay insulation in those areas which will be heated.
4. Place heating mats on the insulation per the layout you pre-
pared. 
Push the supplied stakes through the grommets on the
heating elements, into the sand or insulation base below.
This will secure the elements while the concrete is being
poured.
The heating mats must run flat and smooth on the insula-
tion.
Do not crease, fold or otherwise alter the shape or length of
the heating units.
Ensure that elements are laid out with “this side up” label
facing up.
5. Pour the concrete as normal.
Take extra care not to dig into the heating mat surface or
otherwise damage the heating mats.
Ensure that the heating mats to not fold when surfacing
material is poured.
Do not use the heating mats to accelerate the curing of the
surfacing material as this may lead to cracks and other
structural defects.
Crown or pitch the driveway normally to direct melt water
flow.
6. Prepare the face of the concrete normally, including the cutting
of expansion joints. You may add stone, tile, texture, or other
surfaces to the concrete in accordance with the manufacturer’s
instructions.
When cutting expansion joints, ensure that the blade does not
contact the heating elements.