Trouble. An open door, window, or other
problem on a zone that may prevent arming.
User Program Code. A code (up to 6 digits)
required to enter the Program Mode in order
to program or change Arm/Disarm Codes.
to program or change Arm/Disarm Codes.
Watch Mode (MA1008 and MA1010 only).
Turns all Day Zones on and off simultaneously
by pressing Key [S] twice. (Optional.)
by pressing Key [S] twice. (Optional.)
Zones. Independent circuits that protect
specific areas of the premises:
•
Auto-Bypass Zone: A zone that will auto-
matically be bypassed from the system if
in trouble (faulty) when the system is
armed. (Not available in UL installations.)
matically be bypassed from the system if
in trouble (faulty) when the system is
armed. (Not available in UL installations.)
•
Burglary Zone: Detects intrusion.
•
Day Zone: A zone programmed to cause
visual and audible indication at the keypad
when it is in trouble while disarmed. This
feature is generally used to detect a prob-
lem, such as a break in a window foil, dur-
ing the day. If a Day Zone is open, the
green STATUS light will flash, the sounder
will pulse, and the numerical display will in-
dicate the zone. Hold down Key [9] to si-
visual and audible indication at the keypad
when it is in trouble while disarmed. This
feature is generally used to detect a prob-
lem, such as a break in a window foil, dur-
ing the day. If a Day Zone is open, the
green STATUS light will flash, the sounder
will pulse, and the numerical display will in-
dicate the zone. Hold down Key [9] to si-
lence the sounder and clear the display.
Arm and disarm the panel to re-enable the
Day Zone. (In the MA1008 or MA1010, this
feature may have been programmed so
that Key [9] will turn off only the sounder;
the display will continue to indicate the
open zone until the zone is corrected, at
which time the display will be cleared and
the Day Zone re-enabled.)
Arm and disarm the panel to re-enable the
Day Zone. (In the MA1008 or MA1010, this
feature may have been programmed so
that Key [9] will turn off only the sounder;
the display will continue to indicate the
open zone until the zone is corrected, at
which time the display will be cleared and
the Day Zone re-enabled.)
•
Exit/Entry Zone: Provides exit and entry
delays to permit arming and disarming
without causing an alarm.
delays to permit arming and disarming
without causing an alarm.
•
Exit/Entry Follower Zone: For interior
zones. Ignores detection during exit delay;
ignores detection during entry delay only if
re-entry takes place through the normal
exit/entry door.
zones. Ignores detection during exit delay;
ignores detection during entry delay only if
re-entry takes place through the normal
exit/entry door.
•
Fire Zone: A zone that provides audible
and visual indication at the keypad in the
event of a fire alarm or trouble condition.
The Fire Zone is active 24 hours a day.
and visual indication at the keypad in the
event of a fire alarm or trouble condition.
The Fire Zone is active 24 hours a day.
•
Group-Bypass Zones: Circuits within the
premises, usually including space-protec-
tion devices, interior doors, etc. (but not ex-
premises, usually including space-protec-
tion devices, interior doors, etc. (but not ex-
terior doors or windows) that can all be by-
passed simultaneously by pressing Key [S]
twice. (Not available in UL installations.)
passed simultaneously by pressing Key [S]
twice. (Not available in UL installations.)
•
Never-Arm Zone: (MA1008 and MA1010
only): A zone that will remain disarmed,
even when the rest of the system is armed.
If Chime is programmed, the keypad will
sound while armed or disarmed. This fea-
ture may be used as a driveway monitor,
pool alert, etc.
only): A zone that will remain disarmed,
even when the rest of the system is armed.
If Chime is programmed, the keypad will
sound while armed or disarmed. This fea-
ture may be used as a driveway monitor,
pool alert, etc.
•
Priority Zone: A zone that prevents arming
if in trouble.
if in trouble.
•
Priority Zone with Bypass: A Priority Zone
that can be bypassed by pressing Reset
Key [9] then entering your Arm/Disarm
Code.
that can be bypassed by pressing Reset
Key [9] then entering your Arm/Disarm
Code.
•
Selective-Bypass Zone: A zone that can
be individually bypassed by pressing Key
[S] followed by the zone number.
be individually bypassed by pressing Key
[S] followed by the zone number.
•
24-Hour Zone: A zone that is armed and
ready at all times to respond to an emer-
gency situation.
ready at all times to respond to an emer-
gency situation.
GLOSSARY
5