orcad pspice Benutzerhandbuch

Seite von 436
Setting up analyses
205
The INOISE, ONOISE, DB(INOISE), and DB(ONOISE) 
output variables are predefined for use with noise (AC 
sweep) analysis.
Table 8
Element definitions for AC analysis specific elements
<
ac suffix
>
device symbol
Meaning
Output variable
examples
(none)
magnitude (default)
V(V1)
I(V1)
M
magnitude
VM(CAP1:1)
IM(CAP1:1)
DB
magnitude in decibels
VDB(R1)
P
phase
IP(R1)
R
real part
VR(R1)
I
imaginary part
VI(R1)
Pspug.book  Page 205  Wednesday, November 11, 1998  1:14 PM