50
Panel announces that a sensor is open.
See Sensors section below.
Panel announces System time is not set.
Set the system time.
Control Panel
Panel announces Function not available when Chime Doors is pressed.
No sensors are programmed using sensor type 10 or 13.
Panel announces Function not available when Chime Special Motion is pressed.
No sensors are programmed using sensor type 25.
Panel announces Function not available when LIGHTS Time Activated is pressed.
No time activated lights have been programmed.
Panel announces Function not available when LIGHTS Sensor Activated is pressed.
No sensor activated lights have been programmed.
Panel announces Invalid. Sensor already programmed as Sensor Name.
This sensor is already programmed. Delete sensor if not correctly programmed.
Options (Programmable by the homeowner)
Panel does not beep.
Turn on (add) Option 1.
Latchkey does not function.
Latchkey time (option 3) is not set. Set Latchkey time.
Latchkey is not enabled. Enable Latchkey by pressing ARM Motion Sensors 
twice.
The phone number is not programmed properly. Reprogram the phone number. 
(options 13 or 43)
System Time is not set. Set system time.
Sensors
A sensor does not work.
Make sure the battery is good and installed correctly.
Check for interference from metal objects. Move or rotate the sensor.
Move the sensor to a new location.
Door or window is closed, but the panel announces it is open.
Be certain the arrow on the magnet and the guide line on the transmitter are 
aligned and within 1/4 inch of each other.
The sensor tamper switch may be open (cover off).
Motion sensors go off continuously.
Be sure the sensor is mounted on a solid surface and the viewing field is free from 
sources of changing temperature.
Motion sensor does not respond to motion.
Make sure the sensor battery is good and installed correctly. Wait 2 minutes after 
installing a new battery to test the sensor.
Adjust the sensor mounting.
Leave the area for 3 minutes, then retest.
The environment is too hot or too cold. Outdoor sensors will operate between 32° 
and 120°F.