Furuno 1834C-BB Benutzerhandbuch

Seite von 233
2. RADAR OPERATION 
 
2-22
2.22 Guard Alarm 
The guard alarm allows the operator to set the desired range and bearing for a guard zone. 
When ships, islands, landmasses, etc. violate the guard zone, an audio alarm sounds and 
the offending target blinks to call the operator’s attention. 
CAUTION
• 
The alarm should not be relied upon as
   the sole means for detecting possible
   collision situations.
• 
A/C SEA, A/C RAIN and GAIN controls
  should be properly adjusted to be sure
  the alarm system does not overlook
  target echoes.
 
2.22.1  Setting a guard alarm zone 
To set a guard alarm zone, set the radar to transmit and do the following: 
 
1. Press the ALARM key. 
2. Use the Trackball to set the cursor on the top left corner (or top right corner) of the 
guard zone you want to set, then press the A: SET GUARD1 or C: SET GUARD2 soft 
key, depending on which guard zone you want to set. 
3. Use the Trackball to set the cursor on the bottom right corner (or top left corner) of the 
guard zone area, then push the ENTER knob. 
4.  Press the E: RETURN soft key to finish. 
(1) Drag cursor to top (or bottom) corner
for guard zone and press the A: SET
GUARD1 or C: SET GUARD2 soft key.
The soft keys disappear and the instruction
box appears at left-hand cursor. 
(2) Drag cursor diagonally to bottom (or top) 
corner for guard zone and press the ENTER knob. 
12/
H-UP 
    3nm
LP
319. 9
°
M
317.2 ˚R
 11.60
nm
+
12/
H-UP 
    3nm
LP
39.9 ˚R
    8.800
nm
+
NO ALARM
ALARM
ALARM
GUARD 1
319. 9
°
M
1
MOVE +CURSOR TO
ANOTHER CORNER OF
GUARD1 AND PUSH
KNOB TO SET.
2
RETURN
E
SET
GUARD1
A
SET
GUARD2
C
RETURN
E
SET
GUARD1
A
SET
GUARD2
C
ERASE
GUARD1
B
 
How to set a guard alarm zone 
The equipment then searches for targets inside the guard zone to determine guard alarm 
type. If a target is found inside the guard zone, the guard zone type becomes an “Outward 
guard alarm,” and any target exiting the guard zone will trigger the audio alarm. If no target 
is found, the guard zone type becomes an “Inward guard alarm,” and any targets entering 
the guard zone will trigger the audio alarm. The guard alarm type is shown as G1(G2) IN or 
G1(G2) OUT.