Cisco 15454-DM-L1-38.1= Datenbogen
Cisco Systems, Inc.
All contents are Copyright © 1992–2005 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 10 of 12
Specification
Description
Management
Card LEDs
Failure (FAIL)
Active/standby (ACT/STBY)
Signal fail (SF)
Client port LEDS (bicolor)
Active-no alarms/alarm
DWDM port LEDs (tricolor)
Active/standby (protection card only)/alarm
Red
Green/yellow (Y-protection)
Yellow
Green/red
Green/yellow/red
Power
Protected card
Typical
Maximum
Unprotected card
Typical
Maximum
45W
54W
42W
50W
Operating Environment
Temperature
23 to 131°F
–5 to 55ºC
Humidity
5 to 95% noncondensing
Storage Environment
Temperature
–40 to 185°F
40 to 85°C
Humidity
5 to 95% noncondensing
Table 5.
DWDM Receive Side Optical Performance
OSNR
Guaranteed BER
Input Power Sensitivity
CD Tolerance
10 dB
<10E(–12)
–9 to –23 dBm
—
10 dB
<10E(–12)
–9 to –22 dBm
±1800 ps/nm
10 dB
<10E(–12)
–9 to –21 dBm
±5400 ps/nm
11 dB
<10E(–12)
–9 to –23 dBm
±1800 ps/nm
12 dB
<10E(–12)
–9 to –23 dBm
±5400 ps/nm
14 dB
<10E(–12)
–9 to –30 dBm
—
14 dB
<10E(–12)
–8 to –29 dBm
±1800 ps/nm
14 dB
<10E(–12)
–8 to –28 dBm
±5400 ps/nm
15 dB
<10E(–12)
–9 to –30 dBm
±1800 ps/nm
16 dB
<10E(–12)
–9 to –30 dBm
±5400 ps/nm