Cisco 15454-DM-L1-38.1= Datenbogen

Seite von 13
 
 
Cisco Systems, Inc.  
All contents are Copyright © 1992–2005 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement. 
Page 10 of 12 
 
 
Specification
 
Description
 
Management
 
Card LEDs
 
Failure (FAIL)
 
Active/standby (ACT/STBY)
 
Signal fail (SF)
 
Client port LEDS (bicolor)
 
Active-no alarms/alarm
 
DWDM port LEDs (tricolor)
 
Active/standby (protection card only)/alarm
 
 
Red
 
Green/yellow (Y-protection)
 
Yellow
 
 
Green/red
 
 
Green/yellow/red
 
Power
 
Protected card
 
Typical 
Maximum 
Unprotected card
 
Typical
 
Maximum
 
 
45W
 
54W
 
 
42W
 
50W
 
Operating Environment 
 
Temperature
 
23 to 131°F 
 
–5 to 55ºC
 
Humidity
 
5 to 95% noncondensing
 
Storage Environment 
 
Temperature
 
–40 to 185°F 
 
40 to 85°C
 
Humidity
 
5 to 95% noncondensing
 
 
Table 5. 
DWDM Receive Side Optical Performance 
OSNR 
Guaranteed BER 
Input Power Sensitivity 
CD Tolerance 
10 dB 
<10E(–12) 
–9 to –23 dBm 
— 
10 dB 
<10E(–12) 
–9 to –22 dBm 
±1800 ps/nm 
10 dB 
<10E(–12) 
–9 to –21 dBm 
±5400 ps/nm 
11 dB 
<10E(–12) 
–9 to –23 dBm 
±1800 ps/nm 
12 dB 
<10E(–12) 
–9 to –23 dBm 
±5400 ps/nm 
14 dB 
<10E(–12) 
–9 to –30 dBm 
— 
14 dB 
<10E(–12) 
–8 to –29 dBm 
±1800 ps/nm 
14 dB 
<10E(–12) 
–8 to –28 dBm 
±5400 ps/nm 
15 dB 
<10E(–12) 
–9 to –30 dBm 
±1800 ps/nm 
16 dB 
<10E(–12) 
–9 to –30 dBm 
±5400 ps/nm