Salicru SLC.3000.TWIN 618AA-16 Merkblatt

Produktcode
618AA-16
Seite von 2
RS-232 interface.
Monitoring software.
SNMP adapter / Web. 
(1)
AS-400 card.
USB port card. 
(1)
MODBUS protocol. 
(1)
Temperature-humidity sensor. 
(1)
COMMUNICATIONS
SERVICES
Pre-sale and after sale advisory service.
Multiple formulae for maintenance and
telemaintenance (SICRES).
Extended autonomies. 
(1)
Galvanic isolation. 
(1)
Other input / output voltages. 
(1)
Tower or 19” rack format.
Single or three-phase input.
Redundant parallel system    4 kVA.
ADAPTABILITY
EN 62040-1; EN 60950-1; EN 60529
RS-232
AVDA DE LA SERRA 100 · 08460 PALAUTORDERA · SPAIN · FAX +34 93 8481151
+
34 93 848 24 00
**
902 48 24 00
*
WWW.SALICRU.COM
(*) Spain only (**) R
est of  W
orld
 TECHNICAL SPECIFICATIONS
MODEL
FORMAT
Nominal voltage
Efficiency
Permissible overloads 
(4)
OUTPUT
On-line, double conversion, PFC, double DC bus
220 / 230 / 240 V 
(3)
176 
÷
 276 V
50 / 60 Hz
0.98 
(2)
220 / 230 / 240 V
1 Hz / s
> 88% at full load
Up to 130% for 10 minutes; > 130% for 1 second
Crest factor
3 to 1
Nominal voltage
Permissible voltage range
Permissible frequency range
Overload
Battery type
CHARGER
Technology
Recharging time
GENERALS
220 / 230 / 240 V
± 15%
Up to 130% permanently; > 130% for 1 second
Sealed, maintenance free
P / U (Constant power - Constant voltage)
7 hours up to 90%
Operating temperature
0º C 
÷ 
+ 40º C
Up to 95%, non-condensing
Frequency
Frequency range
Power factor
Rectifier structure
Nominal voltage
Voltage accuracy 
(2)
Maximum slew rate
Synchronisation
Voltage range
SLC TWIN
700 VA -10 kVA
TECHNOLOGY
INPUT
Tower or rack 
(2)
Tower
Total harmonic distortion (THDv) 
(2)
BYPASS
BATTERIES
Protection
Charge type
Ports
COMMUNICATION
Relative humidity
Operating altitude
Safety
Electromagnetic Compatibility (EMC)
Operating
Quality and Environmental management
3 x 380 / 400 / 415 V
3 x 304 
÷
 478 V
± 4 Hz
PFC with Soft Start
± 1%  steady state; ± 2% transient state
Mains present ± 4 Hz; free running ± 0.05 Hz 
(2)
 2% linear load;      6%  non-linear load
(in accordance with EN 62040-3)
50 / 60 Hz ± 4 Hz
Against overvoltages, under voltages and alternating
current component
PWM
8  hours up to 90%
2400 m.a.s.l.
EN 62040-2
ISO-9001 and ISO 14001 TÜV
ON-LINE DOUBLE CONVERSION UPS
700 VA - 20 kVA
DESCRIPTION
UNINTERRUPTIBLE POWER SUPPLY (UPS)
REF. JM629A01   CODE 401AB000403          ED. MAY  2009
SLC TWIN
1. 
AC input.
2. 
AC output.
3.
 Maintenance bypass.
4.
 RS-232 interface.
5.
 Intelligent slot (SNMP, USB, AS-400).
6.
 Data line protection RJ-11/RJ-45.
7. 
Battery module connection.
8.
 Input protection.
9.
 Parallel port.
3
4
5
7
9
Marking
 RANGE
TOWER MODEL
POWER
(VA / W)
SLC - 700 - TWIN
SLC - 1000 - TWIN
SLC - 1500 - TWIN
SLC - 2000 - TWIN
SLC - 3000 - TWIN
SLC - 4000 - TWIN
SLC - 5000 - TWIN
SLC - 6000 - TWIN
SLC - 8000 - TWIN
SLC - 10000 - TWIN
SLC - 12000 - TWIN
SLC - 15000 - TWIN
SLC - 20000 - TWIN
DIMENSIONS
(Dx W x H mm)
WEIGHT
(Kg)
700 / 490
1000 / 700
1500 / 1050
2000 / 1400
3000 / 2100
4000 / 2800
5000 / 3500
6000 / 4200
8000 / 5600
10000 / 7000
12000 / 8400
15000 / 10500
20000 / 14000
13
14
30
31
32
84
87
90
92
93
48 + 131
49 + 131
50 + 131
410 x 145 x 220
410 x 145 x 220
470 x 195 x 347
470 x 195 x 347
470 x 195 x 347
575 x 260 x 717
575 x 260 x 717
575 x 260 x 717
575 x 260 x 717
575 x 260 x 717
575 x 260 x 717 (x 2)
575 x 260 x 717 (x 2)
575 x 260 x 717 (x 2)
INPUT / OUTPUT
II / II
II / II
II / II
II / II
II / II
II / II
II / II
II / II
II or III / II
II or III / II
III / II
III / II
III / II
RACK 19” MODEL
POWER
(VA / W)
DIMENSIONS
(Dx W x H mm)
INPUT / OUTPUT
700 / 490
1000 / 700
1500 / 1050
2000 / 1400
3000 / 2100
4000 / 2800
5000 / 3500
6000 / 4200
16
17
10 + 28
11 + 28
12 + 28
14 + 64
14.5 + 64
15 + 64
SLC - 700 - TWIN R
SLC - 1000 - TWIN R
SLC - 1500 - TWIN R
SLC - 2000 - TWIN R
SLC - 3000 - TWIN R
SLC - 4000 - TWIN R
SLC - 5000 - TWIN R
SLC - 6000 - TWIN R
II / II
II / II
II / II
II / II
II / II
II / II
II / II
II / II
SLC TWIN/3
8 kVA -20 kVA
For platforms Windows family, Linux and Mac
Monitoring software
STANDARDS
Acoustic noise level at 1metre
< 45 dB 
(2)
0.95
< 60 dB
VFI in accordance with 62040-3
450 x 483 x 87 (2U)
450 x 483 x 87 (2U)
450 x 483 x 87 (2U) (x 2)
450 x 483 x 87 (2U) (x 2)
450 x 483 x 87 (2U) (x 2)
600 x 483 x 132 (3U) (x 2)
600 x 483 x 132 (3U) (x 2)
600 x 483 x 132 (3U) (x 2)
WEIGHT
(Kg)
CE
(2) Depending on the model                    (3) Voltage availability of 110 / 115 / 120 / 127 V                   (4) On line mode
(1) Optional
2 kVA tower model
1 kVA rack model
2
1
8
7
4
5
2
6
8
1
6
7
2
1
8
4
5
6 kVA tower model
Data liable to changes without prior notice.
Values for standard autonomies.
For other configurations, consult dimensions and weights
ASK FOR LOCAL
C O N D I T I O N S
W
ARRANTY
Y E A R S