Panasonic S-ICX Handbuch

Seite von 327
Section 700 - Operation
Chapter 3. System Features
S-ICX-50-700
S-ICX (International) issued October 2000
 39
The answering party can operate a connected door opener (if equipped).
Operation
To answer a doorphone:
Hardware Requirements
The doorphone requires a Doorphone Adaptor, Doorphone, and Door Opener. Door openers are 
not sold by Panasonic; however, they can be purchased from an electronics dealer.
Up to 2 Doorphones can be connected to a Doorphone Adaptor and utilize the same trunk.
The Door Opener can be set to open for 15 seconds, 30 seconds, or one minute.
While the Door Opener is functioning, a call from another Doorphone on the same Doorphone 
Adaptor cannot be answered.
Considerations
The trunk connected to the Doorphone Adaptor must be set to dial pulse (DP).
Doorphone Sensor
The sensor is a device that detects when a circuit is opened or closed. Sensors can be used to detect 
events such as the opening of windows or doors. When the sensor is tripped, a tone sounds at a 
designated extension. Sensors are not sold by Panasonic; however, they can be purchased separately 
from an electronics dealer.
Hardware Requirements
The sensor is attached to the Doorphone Adaptor (VB-3473UK).
Trunks connected to the Doorphone Adaptor signal the designated extension when the sensor is 
tripped.
Considerations
The trunk connected to the sensor must be a dial-pulse (DP) trunk.
Extension Interface
The System supports a full array of extension devices including the following:
Panasonic’s proprietary key telephones
Standard analog devices 
Dial Pulse (DP) / Dual Tone Multifrequency (DTMF) Single Line Telephone (SLT)
Integrated Services Digital Network (ISDN) - Basic Rate Interface (BRI) S-point devices
ISDN-Primary Rate Interface (PRI) S-point devices
Action
Result
1.   Answer the doorphone. (Door box calls ring in on a dedi-
cated FF key.)
Two way conversation possible
2.   Enter 3 while connected to the doorphone extension. 
Door unlocks