InstRUMEnt sEtUp
•  Auto mode selects optimal distance range and pulsewidth
•  All settings selected through easy to use menu selections
•  Short pulsewidth (5ns) available for high-resolution 
measurements
•  Color and high intensity monochrome settings for bright 
sunlight conditions 
•  Complete control of fiber analysis settings for auto 
measurement of splice and end of fiber
OtDR tRACE
•  View and measure test results 
•  One button measurement of distance and loss information 
Event View Mode
  Page through each loss event for location in  
(meters/miles and feet) and loss in dB
Manual Measurement Mode
  Perform manual measurement with A and B cursor  
for distance, loss and reflectance measurements
Measurement setup
  View settings used to acquire measurement 
Fiber Analysis software
  View settings used for auto measurement of events
HI-REsOLUtIOn EVEnt VIEwInG
•  Easy to view and measure in high-resolution mode
•  One button to jump to high-resolution view
•  One button jump back to entire trace view
•  0.1 meter sampling resolution
•  Active cursor snaps to the next event in the fiber  
analysis table
OTDR OpeRaTiOn mODes
CABLE ACCEptAnCE REpORt
•  Generate professional OTDR cable acceptance reports
•  Cable acceptance report can be customized by user
•  Trace signature and fiber events are printed on each report
OTDR Cable aCCepTanCe RepORT geneRaTiOn
OtDR tRACE VIEwER
•  View and measure all trace files stored on the 930XC
•  Bellcore Standard OTDR Report (SOR) file storage format
•  Display trace, fiber events and measurement 
information on single screen
•  Display measurement settings used to acquire trace
speCifiCaTiOns
www.greenlee.com
MODEL
930XC-20C
930XC-30F
930XC-30P
930XC-20M
Wavelength (± 20nm)
1310/1550
1310/1550/1625
1310/1490/1550
850/1300
Dynamic Range (dB)
35
38/37/37
38/37/37
21/24
Event Deadzone (m)
1.8
1.5
2.5
1.8
Attenuation Deadzone (m)
10
10
14
8
Pulsewidth
5, 10, 30, 100,  
300, 1us, 2.5us, 10us, 20us
12, 30, 100, 275, 1us/30, 
100, 275, 1us, 2us
Selectable Ranges (km)
0.3, 1.3, 2.5, 5, 10, 20,  
40, 80, 120, 160, 240
0.1, 0.3, 0.5, 1.3, 2.5, 
5, 10/0.1, 0.3, 0.5, 1.3, 
2.5, 5, 10, 20, 40, 80
Average Time
15s/30s/1 min/2 min/3 min
Distance Measurement Accuracy
±(1m + 5 X 105 x distance + sampling space)
Connector Type
PC or APC (interchangeable FC, SC, ST)
Reflection Detect Accuracy
±4 dB
Attenuation Detect Accuracy
±0.05 dB/dB
Measurement Data Storage
1,000 test curves
Data Transmission
RS-232/USB port
Visual Fault Locator (VFL)
3mW; 650nm
Optical Power Meter (OPM)
InGaAs
OPM Wavelengths
850, 1300, 1310, 1490, 1550, 1625nm
OPM Range
+6 to -70dBm (+6 to -60dBm 850nm)
OPM Display resolution
0.01dB
OPM MOD Identification
1kHz, 2kHz
Stabilized laser Source (SLS)
Wavelength same as selected in OTDR mode ≤ -7dBm
Power Supply
NiMH chargeable battery/AC adapter
Battery Life
Support over 8 hours operating on one charge or over 20 hours standby
Operating Temperature
-10° to 50° C
Storage Temperature
-20° to 60° C
Relative Humidity
0 to 95% (non-condensing)
Weight
1.9 lbs. (0.87 kg)
Dimensions
7.7” H x 3.9” W x 2.4” L (196mm x 100mm x 64mm)
Compliance
BelCore GR196, CE, FCC, UL, RoHS, WEEE
Fiber Analysis Software
Version 3.2