Westermo SDW-532-MM-LC2 Rail Switch Техническое Руководство

Seite von 2
Specifications SDW-532
Dimensional drawing 
Power
Operating voltage
9.6 – 57.6 VDC 
12 – 48 VDC
Rated current
SDW-532-MM-SC2-SM-SC15 450 mA  @ 12VDC
SDW-532-MM-SC2 600 mA  @ 12VDC
SDW-532-MM-ST2 600 mA  @ 12VDC
SDW-532-SM-LC15 450 mA  @ 12VDC
SDW-532-SM-SC15 450 mA  @ 12VDC
SDW-532-SM-LC40 450 mA  @ 12VDC
SDW-532-MM-LC2 450 mA  @ 12VDC
Interfaces
Ethernet TX
3 x RJ-45, 10 Mbit/s or 100 Mbit/s
Ethernet FX
2 x LC, SC or ST connectors, 100 Mbit/s
Temperature
Operating
–25 to +70ºC (–13 to +158ºF)
Storage & Transport
–25 to +70ºC (–13 to +158ºF)
Agency approvals and standards compliance
EMC
EN 61000-6-2, Immunity industrial environments
EN 61000-6-4, Emission industrial environments
Safety
EN 60950-1, IT equipment.
Marine
DNV GL rules for classification – Ships and offshore units* 
* Applicable only for 3644-0032, 3644-0033, 3644-0035
34,1
113,6
41,5
121,1
123,4
Dimension W x H x D
34 x 123 x 121 mm (1.33 x 4.84 x 4.76 in)
Weight
0.2 kg
Degree of protection
IP21
SDW-532_1606_EN_REV. B