Dimension W x H x D 52 x 100 x 101 mm  
(2.04 x 3.93 x 3.97 in)
Weight
0.7 kg
Degree of protection
IP40
Specifications L108-F2G-S2 EX
Dimensional drawing 
Power
Operating voltage
19 to 60 VDC
Rated current
250 mA (380 mA) @ 24 VDC (with 500 mA USB load) 
120 mA (188 mA) @ 48 VDC (with 500 mA USB load)
Interfaces
Ethernet TX
4 x RJ-45, 10 Mbit/s, 100 Mbit/s,
Ethernet SFP pluggable connections (FX or TX)
SFP (LC connector), 100 Mbit/s or 1000 Mbit/s transceivers supported
2 Serial ports  
(One configurable for RS-232 or RS-422/485)
1 x RJ-45, RS-232: 
50 bit/s – 115.2 kbit/s
1 x RJ-45, RS-422/485:  50 bit/s – 2 Mbit/s
Digital I/O
1 x 4-position detachable screw terminal
USB
1 x USB 2.0 host interface
Console
1 x 2.5 mm jack, use only Westermo cable 1211-2027
Temperature
Operating
–40 to +70°C (–40 to +158°F)
Storage & Transport
–50 to +85°C (–58 to +185°F)
Agency approvals and standards compliance
EMC
EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus
Safety
UL/IEC/EN 60950-1, IT equipment
Marine
DNV GL rules for classification – Ships and offshore units 
IECEx
Explosive atmosphere  
IEC 60079-0, General requirements 
IEC 60079-15, Equipment protected by type of protection “n” 
IEC 60079-28, Protection of equipment and transmission systems using optical radiation
ATEX
Explosive atmosphere 
IEC 60079-0, General requirements 
IEC 60079-15, Equipment protected by type of protection “n” 
IEC 60079-28, Protection of equipment and transmission systems using optical radiation
Class1 Div 2
FM Approval
92 ±1
Min 4mm
Max 7,5mm
34
±1
96 ±1
52 ±1
100
±1
L108-F2G-S2-EX_1605_EN_REV. B