Westermo RFI-211-F4G-T7G-EX Managed Switch Техническое Руководство
www.westermo.com – A Beijer Electronics Group Company
Specifications RFI-211-F4G-T7G-EX
Dimensional drawing
Power
Operating voltage
16 to 60 VDC
Rated current
0.87 (1.06*) A @ 20 VDC
0.35 (0.43*) A @ 48 VDC
0.35 (0.43*) A @ 48 VDC
* With 500mA USB load
Interfaces
Console
1 x USB Micro-B connector
USB
1 x USB 2.0 host interface
Digital I/O
1 x 4-ports detachable screw terminal
Ethernet
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections transceivers supported,
Ethernet FX or TX SFP.
4 x 100/1000 Mbit/s, pluggable connections transceivers supported,
Ethernet FX or TX SFP.
Temperature
Operating
–40 to +70 °C (–40 to +158 °F)
Storage & Transport
–50 to +85 °C (–58 to +185 °F)
Maximum surface temperature
135 ºC (275 ºF) (temperature class T4)
Agency approvals and standards compliance
EMC
EN 50121-4, Railway applications – Electromagnetic compatibility – Emission and immunity of the signalling
and telecommunications apparatus
EN 55022, Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement
EN 55024, Information technology equipment – Immunity characteristics Limits and methods of measurement
EN 61000-6-1, Electromagnetic compatibility – Immunity for residential, commercial and light-industrial environments
EN 61000-6-2, Electromagnetic compatibility – Immunity for industrial environments
EN 61000-6-3, Electromagnetic compatibility – Emission standards for residential, commercial and light industrial
EN 55022, Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement
EN 55024, Information technology equipment – Immunity characteristics Limits and methods of measurement
EN 61000-6-1, Electromagnetic compatibility – Immunity for residential, commercial and light-industrial environments
EN 61000-6-2, Electromagnetic compatibility – Immunity for industrial environments
EN 61000-6-3, Electromagnetic compatibility – Emission standards for residential, commercial and light industrial
environments
EN 61000-6-4, Electromagnetic compatibility – Emission standard for industrial environments
FCC part 15 Class A
EN 61000-6-4, Electromagnetic compatibility – Emission standard for industrial environments
FCC part 15 Class A
Safety
UL/IEC/EN 60950-1, IT equipment
Marine
DNV Standard for Certification no. 2.4
IECEx
Explosive atmosphere: IEC 60079-0, General requirements
IEC 60079-15, Equipment protected by type of protection “n”
IEC 60079-28, Protection of equipment and transmission systems using optical radiation
IEC 60079-15, Equipment protected by type of protection “n”
IEC 60079-28, Protection of equipment and transmission systems using optical radiation
ATEX
Explosive atmosphere: EN 60079-0, General requirements
EN 60079-15, Equipment protected by type of protection “n”
EN 60079-28, Protection of equipment and transmission systems using optical radiation
EN 60079-28, Protection of equipment and transmission systems using optical radiation
RFI-211-F4G-T7G-EX_1508_EN_REV. B
100
±1
51
±1
105 ±1
121 ±1
134 ±1
122 ±1
33
±1
Max 7,5mm
Min 4,2mm
100
±1
51
±1
105 ±1
121 ±1
134 ±1
122 ±1
33
±1
Max 7,5mm
Min 4,2mm
Weight
1.5 kg
Degree of protection
IP 40
Dimension
134 x 100 x 122 mm (5.25 x 3.93 x 4.80 in)