Westermo Viper-112A-T3G EN 50155 Switch (M12) Техническое Руководство

Seite von 2
Specifications – Viper 112A-T3G
Dimensional drawing 
Technical data
Rated voltage
24 to 110 VDC 
Operating voltage
16.8 to 143  VDC (14.4 to 154  VDC for 100 ms)
Rated current
580 mA at 24 V and 140 mA at 110 V
Power interruption
Class S2 (10 ms hold-up) 
X1 – X12, Ethernet ports
3 Gbps + 9x100 Mbps ports
Backup and restore port
1 x USB
Console port
1 x RS-232
Operating temperature
–40 to +70°C (–40 to +158°F)
Storage & transport temperature
–55 to +85°C (–67 to +185°F)
MTBF
549,000 hours (MIL-HDBK-217F Notice 2); 561,000 hours (IEC 62380)
Ingress protection
IP67
Weight
1.4 kg
Approvals
Climate
EN 50155/IEC 60571 class TX, Railway applications - Electronic equipment used on rolling stock
IEEE 1478 class 1, condition E4 (incl Salt Mist), Environmental conditions for transit rail car 
electronic equipment
EMC
EN 61000-6-2, Immunity industrial environments
EN 61000-6-4, Emission industrial environments
EN 50121-4/IEC 62236-4, Railway signalling and telecommunications apparatus
EN 50121-3-2/IEC 62236-3-2 Railway applications – Rolling stock – apparatus
Tested and verified for Class S1, DB EMC Regulation 06, Commodity team Radio compatibility in 
VDB Rev 1.0 (Shunting Radio). Compliant with SBB requirements.
Tested and verified for Class S1, ÖBB Radio compatability in near field in accordance with ÖBB-
Infrastructure Edition 4, Revision 14 (Shunting Radio)
Tested and verified for FCC part 15
Mechanical  
(Shock and vibration)
EN 61373 category 1, class A
EN 60068-2-27 10 g, 30 ms
Insulation 
(Coordination and test)
EN 50124-1, Railway applications - Insulation Coordination
EN 50155/IEC 60571, Railway applications - Electronic equipment used on rolling stock
Fire protection
EN 45545-2, Fire protection on railway vehicles
VIPER-112A-T3G_1702_EN_REV. B
 56 
 164 
  7
 
 
 100 
 175 
 36 
 65 
 7 
Dimensions
175 x 100 x 65 mm (6.89 x 3.94 x 2.56 in)