Specifications – Viper 212A-P8-HV
Dimensional drawing 
Technical data
Rated voltage
48 to 110 VDC 
Operating voltage
33.6 to 143  VDC (28.8 to 154  VDC for 100 ms)
Rated current
1.9 A at 48 V and 0.8 A at 110 V
Rated PoE power
Max 61.6  W total; max 30 W on a single port
Power interruption
Class S2 (10 ms hold-up) for switch and connected PoE devices
X1 – X12, Ethernet ports
12x100 Mbps ports (whereof 8 PoE)
Backup and restore port
1 x USB
Console port
1 x RS-232
Operating temperature
–40 to +70°C (–40 to +158°F)
Storage & transport temperature
–55 to +85°C (–67 to +185°F)
MTBF
403,000 hours (MIL-HDBK-217F Notice 2)
Ingress protection
IP67
Weight
1.7 kg
Approvals
Climate
EN 50155/IEC 60571 class TX, Railway applications - Electronic equipment used on rolling stock
IEEE 1478 class 1, condition E4 (incl Salt Mist), Environmental conditions for transit rail car 
electronic equipment
EMC
EN 61000-6-2, Immunity industrial environments
EN 61000-6-4, Emission industrial environments
EN 50121-3-2/IEC 62236-3-2 Railway applications – Rolling stock – apparatus
Tested and verified for Class S1, DB EMC Regulation 06, Commodity team Radio compatibility in 
VDB Rev 1.0 (Shunting Radio). Compliant with SBB requirements.
Tested and verified for Class S1, ÖBB Radio compatability in near field in accordance with ÖBB-
Infrastructure Edition 4, Revision 14 (Shunting Radio)
Tested and verified for FCC part 15
Mechanical  
(Shock and vibration)
EN 61373 category 1, class A
EN 60068-2-27 10 g, 30 ms
Insulation 
(Coordination and test)
EN 50124-1, Railway applications - Insulation Coordination
EN 50155/IEC 60571, Railway applications - Electronic equipment used on rolling stock
Fire protection
EN 45545-2, Fire protection on railway vehicles
VIPER-212A-P8-HV_1611_EN_REV. A
Dimensions
177 x 100 x 110 mm (6.97 x 3.94 x 4.33 in) 
 164 
 100 
  7
 
 
 56 
 82 
 110 
 177 
 3