HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. 
However, recharging the battery for at least four hours is recom-
mended to insure that the battery’s maximum charge capacity is 
achieved. Charge loss may occur during shipping and storage. 
To recharge the battery, simply leave the unit plugged into an 
AC outlet. The unit will charge in both the ON as well as the OFF 
position. If you wish to use the software, connect the enclosed 
USB cable to the USB port on the UPS and an open USB port on 
the computer.
2. With the UPS unit OFF and unplugged, plug your equipment 
into the unit’s rear panel AC outlets. DO NOT plug a space heater, 
vacuum cleaner, paper shredder or other large electrical device 
into the UPS. The power demands of these devices will overload 
and possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall 
outlet). Make sure the wall branch outlet is protected by a fuse 
or circuit breaker and does not service equipment with large 
electrical demands (e. g. refrigerator, copier, etc.) Avoid using 
extension cords. If used, the extension cord must be UL or CSA 
Listed, minimum 14 AWG, 3-wire grounded, and rated for 15 
Amps.
Installing Your UPS
4. Press and hold the power switch for 2 seconds to turn the 
UPS on. The display will say “Initializing”, followed by the 
normal operation screen.
5. The rear panel circuit breakers will open and power to the 
connected equipment will be turned OFF if an overload is 
detected. To correct this, turn the UPS off, unplug at least one 
piece of equipment, wait 10 seconds, check to make sure that the 
circuit breakers are reset, and turn the unit on.
6. The UPS will automatically charge the battery whenever it is 
plugged into an AC outlet.
7. To maintain optimal battery charge, leave the UPS plugged 
into an AC outlet at all times. 
Note: To store your UPS for an extended period, cover it and 
store with the battery fully charged. Recharge the battery every 
three months to ensure battery life.