Panamax MB1000 Benutzeranleitung

Seite von 17
7
2. If the delay settings are the same for both IR1 and IR2, the IR2 
code will be sent to both outputs 2 seconds after IR1.
3. The IR commands will also be transmitted immediately after 
the battery charge falls below the critical load battery threshold. 
This ensures that equipment will be shutdown properly if the 
UPS’s load level is extremely high and the backup time would be 
less than the selected IR output delay.
4. There is no IR output after the power is restored to the system.
To program IR output:
1. From the setup menu, turn the Menu Navigation Knob until 
IR1 Setup is displayed. Push the Menu Navigation Knob to 
select.
2. Turn the Menu Navigation Knob until IR1 Program is dis-
played. 
3. The screen will display the message “READY TO SAMPLE 
REMOTE”. Press the button on the remote.
4. If the signal was learned, then the screen will display the 
message “IR1 SAMPLED” and advance to the “TEST IR” screen. 
Press the navigation knob to test.
5.If the signal was not learned, the screen will display the mes-
sage “IR1 SAMPLE FAIL”, then it will return to the IR1 Program 
screen. Repeat steps 3 and 4.
6.To program another IR device, from the Setup menu, turn the 
Menu Navigation Knob until IR2 Setup is displayed.  Follow 
steps 3-5.
Advanced Operation
RS-232 Control with Open Protocol
The RS-232 serial interface can be used in the following ways:
1. Initial system setup. An installer can use a notebook comput-
er to set the variables within the Power Control software. Once 
the setup is completed, the notebook computer can be discon-
nected. All settings are stored in the UPS.
2. Connection to a PC or Network: Functionality is very similar 
to a standard UPS with a PC.
The UPS can provide continued power to maintain recording 
capabilities of any number of devices in the event of a black out 
or brown out. It is also capable of saving open documents and 
shutting down the PC during extended power failures. This re-
quires a permanent RS232 connection to the PC and having the 
Power Control software running in the background on the PC. 
(Windows based OS only; Mac Energy Saver software compat-
ible)
3. Integration with sophisticated automation systems like AMX 
and Crestron:
The serial communications command set and protocol is open 
and is published later in this manual. This information can be 
used by the automation system programmer for both UPS control 
by the automation system and reporting of power events by the 
UPS to the automation system.
RS-232 Communications Protocol & 
Command Set