FREQUENCY
Low Cut Enable Switch
The LOW-CUT switch inserts or removes the 12 dB per octave 50 Hz low-cut filter from 
the signal path. When the LOW-CUT switch is pushed in, the LOW-CUT filter is IN the 
audio path.
 Section 3 - Connecting the EQ to Your System
The 2-Series Equalizers have balanced inputs and impedance balanced outputs that can 
be used with any balanced or unbalanced line-level device. 
To connect the equalizer to your sound system refer to the following steps:
r 5VSOPGGBMMFRVJQNFOUCFGPSFNBLJOHDPOOFDUJPOT
r .PVOUFRVBMJ[FSJOBTUBOEBSEXJEUISBDL
        Install the EQ in a rack with the rack screws provided. It can be mounted above 
or below anything that does not generate excessive heat. Ambient temperatures 
should not exceed 113° F (45°C) when equipment is in use. Although the unit’s 
chassis is shielded against radio frequency and electromagnetic interference, 
extremely high fields of RF and EMI should be avoided.
r .BLFBVEJPDPOOFDUJPOTWJB9-3PS534KBDLT BDDPSEJOHUPBQQMJDBUJPO
 OFFET
        Both types of connectors for the inputs and outputs can be used for balanced or 
unbalanced connections. The use of more than one connector at a time for the 
inputs could unbalance balanced lines, cause phase cancellation, short a conduc-
tor to ground, or cause damage to other equipment connected to the equalizer. 
More than one output may be used simultaneously as long as the combined paral-
lel load is greater than 2 k
7.
r 4FMFDUUIFPQFSBUJOHSBOHFXJUIUIF#PPTU$VUSBOHFTFMFDUJPOTXJUDI
/05&#FTVSFUPSFEVDFBVEJPMFWFMTBUUIFQPXFSBNQMJGJFSTXIFODIBOHJOH
UIFTFUUJOHPGUIJTTXJUDIBTJUNBZHFOFSBUFBOBVEJCMFUSBOTJFOU
r "QQMZQPXFSUPUIFFRVBMJ[FS
        Connect the AC power cord to the AC power receptacle on the back of the equal-
izer. Route the AC power cord to a convenient power outlet away from audio lines.  
User Manual
2-Series