Sony E 10-18 mm f/ 4 OSS Lens Gebrauchsanleitung

Seite von 97
4-24
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
4-4-2. Flange Back (f’F) Adjustment
Equipment
• 1000 mm Collimator
• Flange Back Tester
• A-mount Attachment
• Flange Back Gauge (43.50mm)
Note:
Perform the flange back value (f’F) adjustment after completing “4-4-3. Focus-Shift Adjustment”.
1. Adjustment Procedure
1)
Perform “4-4-1. Flange back (f’F) Check” and confirm that the flange back value (f’F) of lens to be checked does not meet the
specification in Table 4-4-1.
2)
Set the focus of lens to be checked to the infinite end.
3)
Viewing the microscope, turn the knob of flange back tester to focus.
4)
Using the formula below, calculate the shift amount (X).
Shift amount (X) = f’F (measured value) with focal length “24 mm” at the infinite end - 44.66 mm
X = Shift amount to be adjusted by the back washer
5)
According to the result in step 4), adjust the thickness of back washer
Note:
Measure the thickness of back washer with a micrometer (or a caliper). (Refer to Table 4-4-2.)
• In case of negative value (-) of shift amount (X), make the back washer thinner by x.
• In case of positive value (+) of shift amount (X), make the back washer thicker by x.
Back Washer
Part No.
Description
t (mm)
2-688-527-01
WASHER (A), BACK
0.05
2-688-528-01
WASHER (B), BACK
0.07
2-688-529-01
WASHER (C), BACK
0.1
2-688-530-01
WASHER (D), BACK
0.2
2-688-531-01
WASHER (E), BACK
0.5
Table 4-4-2
6)
Calculate thickness of coupler adjustment washer by the formula below, and replace the coupler adjustment washer.
Thickness of coupler adjustment washer = Thickness of back washer - 0.25 mm
Coupler Adjustment Washer
Part No.
Description
t (mm)
2-684-057-01
COUPLER ADJUSTMENT WASHER
0.05
2-684-058-01
COUPLER ADJUSTMENT WASHER
0.07
2-684-059-01
COUPLER ADJUSTMENT WASHER
0.1
2-684-060-01
COUPLER ADJUSTMENT WASHER
0.2
2-684-061-01
COUPLER ADJUSTMENT WASHER
0.5
Table 4-4-3
7)
Insert the back adjustment washer, and perform “4-4-1. Flange back (f’F) Check”.