complex antenna analyzers during installation and allows remove and continuous monitoring of
the antenna during operation.  If the antenna or the coaxial feed-line are damaged, the Gateway
will detect the condition and issue an alarm.
The coaxial cable connecting the antenna to the gateway should have low loss at 902-928MHz.
Only high quality cable such as LMR400 should be used.  Many popular calculators are available
on-line to determine the loss a given type of cable will cause at 915MHz for example:
http://www.timesmicrowave.com/cgi-bin/calculate.pl
Although N-connectors are waterproof and designed for rugged outdoor operation, it is often
desirable to further waterproof the connections; heat-shrink tubing with internal glue is often used
to seal the connection between the cable and the connector.   
The antenna should be
mounted as high as possible.
The antenna should not be
placed close to other objects
(including the pole itself);
other metal objects in close
proximity to the antenna will
result in particularly poor
performance.
If the antenna cannot be
mounted at the top of a pole, it
should be mounted on an arm
that places the antenna as far
from the pole as possible.
Refer to the diagrams to the
right for examples of good and
bad antenna mounting
practices.
Lightning Arrestor
A lighting arrestor should be
mounted to the N-Connector
on the Gateway chassis and the other end connected to the antenna cable.  The lightning
arrestor must be grounded using a 12-14 AWG solid core wire to a high quality ground.  Failure
to use a lightning arrestor and ground cable will void the
Gateway warranty and may create hazardous conditions.
The lightning arrestor may be grounded directly to the pole if the
pole is metal and is itself grounded; if the arrestor is not
grounded, the Gateway chassis grounding will provide the
ground path for any antenna discharges which may result in
damage to the Gateway's sensitive radio circuitry.