3) Low battery alarm 
If the battery voltage becomes considerably low, the LED display blinks red and the U-WAVE-T sends   
a low battery alarm error to the U-WAVE-R. Immediately replace the battery. 
(The buzzer type alarms a low battery voltage with a buzzer sound along with a blinking LED.)
 
IMPORTANT 
  Always use the CR2032 battery (lithium battery). 
•  The battery supplied at the time of purchase is to check the functions and performance of the 
U-WAVE-T. The predetermined length of life may not be met. 
•    Even for the used CR2032 battery, its voltage may recover in a short time after it is removed from 
the U-WAVE-T. However, do not continue to use the old battery. Be sure to replace the battery   
with a new one.       
•  Upon disposal of the battery comply with the related ordinance, regulation, etc. 
•  When removing or setting the battery, exercises care so as not to break or bend the battery terminal 
by applying an undue force to it. 
 
  [3] Connect the Connecting cable to U-WAVE-T 
•  After loaded with the battery, connect the connecting cable (option
, details see section 8) 
IMPORTANT 
When installing the U-WAVE-T using the connecting cable (02AZD791A, B), particularly   
pay attention to the cable orientation. If the cable is connected in the reverse orientation,   
data cannot be transmitted. 
Black-marked side    => U-WAVE-T 
Gray-marked side   => Measuring tool 
 
 
 
 
 
 
 
 
• 
Set up the connecting cable with the following procedure. 
When screwing or unscrewing the screws, always use the size 0 screwdriver of the   
standard accessory and tighten or loosen them with a torque of 5 to 8 N•cm. 
(1)  Remove the two mounting screws (M1.7X0.35X2.5/No.A115-1712C) of the connector cover with 
the size 0 screwdriver. 
(2)  Dismount the connector cover. 
(3)  Check that the packing (No. 09GAA374) has been attached correctly to the specified position. 
(4)  Connect the connecting cable with the U-WAVE-T. 
(5)  While pressing the connecting cable end with fingers, tighten the cable fixing screws so that no gap 
appears between the cable connector and the U-WAVE-T. 
(6)  Make sure that no part of the packing is detached. 
 
  (1)   
 
 
       
(5) 
 
 
 
 
[4] Register the setting information of U-WAVE-R 
After loaded with the battery and connected to a connecting cable, the U-WAVE-T needs to register the 
setting information of U-WAVE-R. 
Please read the “U-WAVEPAK User’s Manual“ in “PDF_Manual” folder of the CD supplied as a standard 
accessory of U-WAVE-R for a detailed registering method and content. 
“Adobe Reader” of Adobe Systems INC. is necessary to read. 
IMPORTANT 
• “Registering the setting information” should be performed by DATA switch of the connecting 
  cable before connecting to the Measuring tool.   
  • The registered information is stored after changing battery. 
 
[5] Connecting to Measuring tool 
 
• After registering the setting information, connect the U-WAVE-T to the Measuring tool.   
  • Clamp the cable leading to a Measuring tool using the supplied cable clamp or a Velcro fastener so 
that measurement is not interfered and the LED display of the U-WAVE-T can be easily viewed.     
[6] Functions 
1) Data communication 
The U-WAVE-T performs data communication with DATA switch as shown below
.
 
Operations 
DATA switch push-down time t 
LED 
Transmits measurement data. 
  t ≤ 2sec 
None 
Transmits the Cancel command. 
2 sec < t ≤ 5 sec 
Orange blinking 
0.1 sec interval 
Executes U-WAVE-R search.   
5 sec < t ≤ 10 sec 
Orange blinking 
0.3 sec interval 
NOTE 
• The Cancel command is a command to inform a U-WAVE-R of data error when wrong  
measurement data is transmitted to the U-WAVE-R due to an operating error. However, the   
wrong measurement data is not canceled by the command. It is to inform that the previous   
data is different from measuring value.      
• When the U-WAVE-R search is executed, U-WAVE-T is connected with U-WAVE-R that   
 can be registered. 
• If the DATA switch is held down for more than 10 seconds, the orange LED stops blinking   
and nothing will function. 
 
The U-WAVE-T can check whether to have performed normal communication with a   
U-WAVE-R by a specific LED display (and buzzer sound).   
However, buzzer sounds are available only for the buzzer type U-WAVE-T. 
Description of state 
LED 
Buzzer sound 
Wireless communication has been 
properly completed. 
Green LED blinking 
Short 2 times 
• Wireless communication has failed. 
• An error has occurred. 
Red LED blinking 
Long 1 time 
2) Initializing the setting information 
If communication is disabled while using the U-WAVE-T, first refer to Troubleshooting 
In U-WAVE-R User’s Manual, if communication is still disabled, initialize the setting information 
registered in section 4 to default settings, and then retry communication. 
Initialize the setting information with the following procedure. 
(1) Remove the battery being loaded. For information about how to remove the battery, refer to 
section 2. 
(2) While holding down the DATA switch on the connecting cable connector, reload the battery in 
place. The setting information is initialized. 
(3) Remount the battery cover, and set up the U-WAVE-T. 
IMPORTANT 
Once initialization is performed, the setting information used until then is all cleared. 
 
Mitutoyo Corporation
 
20-1, Sakado 1-Chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan 
 
[7] Specifications 
1) U-WAVE-T for Japan and EU (02AZD730A , 02AZD880A) 
Country 
Japan, Europe 
Model 
IP67 type 
Buzzer type 
Code No. 
02AZD730A 
02AZD880A 
Certification number 
005NYCA0474(Japan) 
005NYCA0476(Japan) 
Protection class 
IP67 
With/without buzzer 
Without 
With 
Transmission output 
Less than 1 mW (0 dBm) 
Distance of communication
Approx. 20 m (line-of-sight distance under office environments) 
A Conformity standard 
Japan
   ARIB  STD-T66 
Europe   
EN 50371:2002 
         EN 300 440-1 V1.3.1 and EN 300 440-2 V1.1.2 
                  EN 301 489-01 V1.6.1 and EN 301 489-03 V1.4.1 
2) U-WAVE-T for U.S.A and Canada (02AZD730C , 02AZD880C) 
Country 
U.S.A, Canada 
Model 
IP67 type 
Buzzer type 
Code No. 
02AZD730C 
02AZD880C 
Certification number 
VXU-02AZD730C (U.S.A) 
4396B-02AZD730C (Canada) 
VXU-02AZD880C (U.S.A) 
4396B-02AZD880C (Canada) 
Protection class 
IP67 
With/without buzzer 
Without 
With 
Transmission output 
Less than 0.5 mW (-3 dBm) 
Distance of communication
Approx. 14 m (line-of-sight distance under office environments) 
A Conformity standard 
U.S.A
  ・47 CFR Part 15.247:(Subpart :C)  ・47 CFR Part 15,(Subpart :B) 
Canada
RSS-210 (Issue 7) and RSS-Gen (Issue 2)  ・ICES 003 (Issue 4)
3) Common Specifications 
Item 
Description 
Wireless communication protocol 
IEEE802.15.4 compatible 
Communication frequency 
2.405 to 2.475 GHz 
Used band 
15 channels (at intervals of 5 MHz) 
Modulation method 
DSSS (Direct Sequence Spread Spectrum) 
Wireless communication speed 
250 Kbps 
LED display 
Green/orange/red: 3 discrete color display 
Battery 
CR2032 (3V): 1 piece 
Battery life 
400,000 times 
Operating temperature (humidity) 
0 to 40°C (20 to 80%RH, with no condensation) 
Storage temperature (humidity) 
-10 to 60°C (20 to 80%RH, with no condensation) 
External dimensions 
44 X 29.6 X 18.5 (mm) 
U-WAVE-T mass 
Approx. 23 g 
4) Standard accessories 
User’s manual (this manual)    No. 99MAL108B2      ・Size 0 screwdriver    No. 05CZA619 
Lithium battery   
 
 CR2032C(B)N     ・Warranty card 
5) Optional accessories         
No. 02AZD790A to G: Connecting cables (For details see section 8.) 
[8] Connecting Cables 
As for connecting cables, it is necessary to select a cable compatible with a Measuring tool to be used. 
Use an appropriate connecting cable from among those in the following table. 
 
 
U-WAVE-T side 
Measuring tool side 
(The connector shape and color differs depending on the 
Measuring tool to be used. ) 
Black 
DATA switch 
Parts No. Model 
Series No,
Product Name 
02AZD790A 
Water-resistant type 
  with data out switch type
Color: Light gray
 
500 
500 
571 
572 
573 
ABS Coolant Proof Caliper                  CD-PMX/PM/GM 
Super Caliper                                     CD-SPM 
ABS Coolant Proof Depth Gage 
VDS-PMX
ABS Coolant Proof Digimatic Scale Units 
SD-G
ABS Coolant Proof Exclusive Caliper 
NTD-PMX/PM
02AZD790B 
Water-resistant type with 
data out switch type 
Color: Light gray
 
293 
293 
--- 
329 
350 
--- 
468 
Coolant Proof Micrometer 
MDC-MJ/MJT
Coolant Proof Micrometer 
MDE-MJ
Coolant Proof Exclusive Micrometer    (The end of the mark is –MJ)
Depth Micrometer 
DMC-M
Coolant Proof Digimatic Micrometer Heads          MHN-M/MJ/MJN
Digimatic Exclusive Micrometer                     (The end of the mark is –M/PM)
Digimatic Holtest 
HTD-R
02AZD790C 
With data out switch type 
 
500 
571 
572 
573 
--- 
ABS Digimatic Caliper                                                          CD-CX/C 
ABS Digimatic Depth Gage                                             VDS-/DCX/DC 
ABS Digimatic Scale Units                                            SD-D/SDV-D 
ABS Digimatic Caliper                                                              CD-SC 
ABS Digimatic Exclusive Caliper                   (The end of the mark is –CX/C) 
02AZD790D 
 
10 pins type 
 
178 
179 
318 
515 
518 
519 
542 
543 
544 
544 
 
572 
574 
Surftest                                SJ-201/301/401/402 
Digi-Derm                                                                                      DGE 
Litematic                                                                            VL-A/AS/AH 
CERA Height Master                                                                HMD-C 
QM-Height                                                                                  QMH-S 
Digital Mu-Checker                                                                              M
Display Unit                                                                        EB/EC-D/EF
Digimatic Indicator                                                                  ID-H/ID-F
Laser Scan Micrometer                                                        LSM-9506
Laser Scan Micrometer                       LSM-6200/6900
(It applies when using Digimatic Codeout unit.(02AGC840)) 
Difference/Sum Unit                                                                    SD-U1
Heightmatic                                                                                      HDF
02AZD790E 
 
6 pins type 
 
164 
227 
227 
293 
293 
 
--- 
339 
337 
468 
515 
568 
810 
810 
Digimatic Micrometer Heads 
MHD-M
Digimatic Micrometer Heads 
CLM-MH
Soft-Touch Micrometer 
CLM
Quickmike MDQ
Exclusive Quickmike 
The end of the mark is –QM) 
Digimatic Micrometer 
MDC-M
Digimatic Exclusive Micrometer 
The end of the mark is -DM)
Digimatic Tubular Inside Micrometer 
IMJ-M
Digimatic Tubular Inside Micrometer 
IMZ-M
Digimatic Holtest 
HTD
Digital Height Master 
HME-DM
ABS Borematic 
SBM-C
Hardness Testing Machine 
HM-100/200/HV-100/HH-411 
Rockwell Type Hardness Testing Machines 
HR-500
02AZD790F 
A frat form straight type 
 
192 
500 
511 
543 
543 
550 
551 
552 
570 
547 
572 
574 
575 
811 
Digimatic Height Gage                                                  HDM-A/HD-A 
Digimatic Caliper 
CD
ABS Digimatic Bore Gage 
CG-D
ABS Digimatic Indicator 
ID-S
ABS Digimatic Indicator 
ID-C
Digimatic Caliper 
CD
Digimatic Caliper 
CD
Digimatic Carbon Fiber Caliper 
CFC
ABS Digimatic Height Gage   
HDS-HC/C
ABS Digimatic Depth Gage 
ABS Digimatic Scale Units 
SD-E/SDV-E/SD-V/SDV-F
Heightmatic HDF-N
ABS Digimatic Indicator 
ID-U
Hardness Testing Units 
HH-300
02AZD790G 
Water-resistant type with 
frat form straight type 
 
543 
ABS Digimatic Indicator 
ID-N/ID-B
 
KAWASAKI, JAPAN