4.4 Packed unit
According to 2M2 EN60721-3-2
5. REGULATION
5.1 Safety Specifications
Table 5.1
Safety standards
IEC60950-1、FCC Part 15 Class B、
CISPR 11 Group 1 Class B
CISPR 11 Group 1 Class B
Approvals
FCC、CB (NCB Lab.)
Protection class
class III
Degree of protection to
IEC 60529
IEC 60529
IP21
Conformity
CE
5.2 Electromagnetic Compatibility
The unit shall comply with CISPR 11 Group 1 Class B - 3dB for conducted and radiated emission.
The unit shall be evaluated for immunity according IEC61000-4-6 against:
The unit shall be evaluated for immunity according IEC61000-4-6 against:
a) Normal performance within limits specified by the manufacturer, requester or purchaser; Section
9, meet level a) Specified as: "Normal operation of the monitor and touch panel should be
maintained during the emissions test."
maintained during the emissions test."
5.3 RoHS Compliance
Comply with RoHS
6. MTBF & Warranty
Flat screen without Backlight: >60,000 operation hours.
The monitor life time: ≥20,000 hours (Brightness reduction to 50%)
Warranty items refer to related service contract.
7. DEFECT, SCRATCH and DUST
7.1 Environment condition
Room temperature: 20 ~ 25°C.
Humidity: 65±5% RH.
Illumination: Fluorescent light (Day-Light Type) display surface illumination to be 300 ~ 700 lux.
(standard 500 lux.)
To be a distance about 35 ± 5 cm in front of LCD unit, viewing line should be perpendicular to the
surface of the module judge the visual appearance with human’s eyes.
Take off the protector of polarizer while judging the display area.
If there is any question while judging, check the panel again while operating.