Shenyang Torch-Bigtide Digital Technology Co. Ltd. 25LCDHL1530 Benutzerhandbuch

Seite von 25
 
Last change:   
2013-12-10 
Copyright @ Shenyang 
Torch-Bigtide Digital Tech.,Co.,Ltd
HL1530 
Page 23 of 25
 
7.2.3 Appearance specification 
 
 
 
 
 
 
 
 
 
 
 
Table 7.3 
Defect pattern 
Condition 
Criteria 
d<0.2mm 
Allowed 
0.2mm ≤d<0.3mm 
≤10 points 
0.3mm ≤d≤0.5mm 
≤3 points 
Dot shape 
d>0.5mm 
0 point 
W<0.05mm 
L<0.7mm 
Allowed 
0.7mm ≤L≤1.0mm 
≤4 points 
0.05mm ≤W≤0.1mm 
L>1.0mm 
Impure ingredient 
Stains 
Dust 
Line shape 
W>0.1mm 
0 point 
d<0.2mm 
Allowed 
0.2mm ≤d≤0.5mm 
≤2 points 
Bubbles, Wrinkles, Dent 
d>0.5mm 
0 point 
S≤0.2
mm2 
Allowed 
Scratch(Surface of polarizer) 
S>0.2
mm2 
0 point 
 
Note1: Definition of symbols is as follows. 
  d: 
Average 
diameter 
(This diameter is the average length of a long axis and a short axis in each defect pattern.) 
 
 
W: Width, L: Length, S: Area 
Note2: Inspection conditions are as follows. 
Table 7.4
 
Temperature 
25±5℃ 
Inspection viewing distance 
20cm (The distance between the inspector’s eye and screen.) 
0°≤θR≤45°, 0°≤θL≤45° 
Inspection direction 
0°≤θU≤45°, 0°≤θD≤45° 
Illumination 
700lx(at an inspection desk surface)