Boiler Diagnostics 
 
Once the amber light is flashing, the hub is set up and you can move on to the 
next installation step. 
 
Hub Lights  What does this mean 
Notes 
No lights 
No power to hub 
Check that all cables are 
connected and that the power 
socket works. 
Green 
flashing 
Installation and start up. 
The hub is attempting to 
connect to the servers and 
update itself. 
Do not disconnect the hub. If 
flashing continues after 15 
minutes, use the Hive Engineer 
App or contact Technical 
Support to confirm it has 
connected 
Amber 
flashing 
Installation. The hub is 
trying to connect to a BDM 
module. 
Confirm that the BDM is 
correctly installed. The hub will 
search for devices for 2 hours at 
a time. It will then pause and 
show solid amber. 
Amber 
solid 
Installation. The hub has 
paused its search for a BDM 
module. 
To restart the search on a 
freshly installed hub, turn the 
hub off and on. Amber flashing 
light should then return. 
Green 
solid 
Normal operation. The hub 
is connected. 
BDM module is installed. 
Red 
Error. The hub has failed to 
connect to the Hive servers. 
Check the hub is plugged in and 
the broadband connection is 
working. Call Technical Support 
if problems persist. 
 
Wait for an amber flashing 
light. During start up the 
green light will flash, followed 
by the amber light. This 
usually takes 5-10 minutes.