Selex ES SPA F567DHDE-HP Benutzerhandbuch
SELEX Communications
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed
by SELEX Communications S.p.A. in writing
51
July 2010
Red
TX fail
RF exciter failure:
- bad power out
- ACP failure
- Exciter PLL unlock
- bad power out
- ACP failure
- Exciter PLL unlock
Red
blink
blink
TX fail
TX dynamic equalizer failure
3
Green
Status 1
RF signal with analog modulation present at the receiver
Red
RX inhibit
Receiver is in inhibited state
4
Green
Status 2
RF exciter correctly On Air with digital modulation
Red
Tx inhibit
Exciter is in inhibited state
5
Green
Status 3
Reserved
Red
Data bus fail
The multichannel data bus is out of frame sync
6
Green
Status 4
Reserved
Red
Logic fail
One of the these error is present:
- DSP/uP communication failure
- logic PLL unlock
- DSP/uP communication failure
- logic PLL unlock
Red
blink
blink
Logic fail
One of the these error is present:
- boot failure
- EEPROM failure
- boot failure
- EEPROM failure
7
Green
Control bus busy
Activity on the control bus
Red
Control bus fail
control bus among the modules is in failure
Red
blink
blink
Control bus fail
Bad message received
8
Green
Upload
Firmware upload in progress
Red
Upload fail
Firmware upload failed
7.1.7 Power Amplifier module - PA
The “Power Amplifier” (PA) module is a wide band RF amplifier in VHF (136 - 170 MHz).
Their time of TX ramp up/down is less than 1200 μsec. This makes the module compatible with the
stringent demands of digital transmission.
Thanks to a microprocessor mounted on board, the module is able to implement the PUFF technology
(Powerful Universal Forming Function) for the shaping of transient power in order to obtain compliance
with the rapid transient rules of ACP (Adjacent Channel Power).
The microprocessor also manages completely the operation of the module: this would remove any
calibration procedures. All configuration changes are performed via software.