Ecolink Intelligent Technology Inc. WST612 Benutzerhandbuch

Seite von 2
WST-612
 
Flood and Freeze Sensor
 
patent pending
 
Installation Manual & Users Guide 
 
SPECIFICATIONS
 
Frequency: 345 MHz 
Operating Temperature: 32°-120°F (0°-49°C) 
Battery: One 3Vdc lithium CR2450 (620mAH) 
Operating Humidity: 5-95% RH non condensing 
Battery life: up to 10 years 
Compatible with Honeywell and 2GIG 
 
Detection of standing Water within 1 second   
Supervisory signal interval: 64 min(approx.) 
  Across Gold probes 
Maximum current draw:  23mA during transmission
 
Detect Freeze at 5C restores at 7C
 
Water resistant to XXX 
 
OPERATION
 
The 
WST-612 
sensor  is  designed  to  detect  water  across  the  gold probes  and  will  alert  immediately  when  present. 
The Freeze sensor will trigger when temperature is below 5C and will send a restoral at 7C. 
 
 
ENROLLING 
 
To enroll the sensor, set your panel into sensor learn mode.  Refer to your specific alarm panel instruction manual 
for  details on these menus.  On the WST-612, locate the vertical line on the side of the sensor. This indicates the 
location of the internal reed switch. To learn in the flood sensor, initiate a transmission by tapping the included 
magnet to this spot. Repeat as needed by the control panel. The flood sensor will enroll as Loop 1. To learn in the 
freeze sensor, initiate a transmission by holding the magnet to the reed for at least 2 seconds. The freeze sensors will 
enroll as Loop 2. You can also trigger the unit by placing a wet finger across the gold probes for a few seconds. 
Since the flood/freeze are two sensors in one, you will need to enroll them as TWO separate sensors if you desire to 
use them both.  **CURRENT SAMPLES DO NOT SUPPORT 2 SECOND FREEZE ENROLLMENT, MUST BE ENROLLED BY 
MANUALLY ENTERING THE SERIAL NUMBER ****
 
 
 PLACEMENT 
  
Place the flood detector anywhere that you wish to detect a flood or freezing temperature.  Under a sink,      
 in or near a hot water heater, a basement or behind a washing machine.  If you would like to make sure the flood     
does not move from its intended location you can use the provided sensor cover and mount it to the wall or floor   
 
 
 
 
Water Height Adjustment 
The Firefighter comes with 2 sets of rubber feet that can be used to adjust the height of the probes to either 3/16
th
 in 
or 3/8
th
 in. Place the rubber feet in the position shown below if you wish to raise the detection level of water  
 
 
 
 
 
 
 
Testing the unit 
By using the magnet you can send a Flood OR Freeze transmission. Place the magnet on the line on top of the 
case and remove it within 1 second, this will send a Flood transmission (Loop1), if you hold the magnet for 2 
seconds, it will send a Freeze transmission (Loop2). Placing wet fingers on any two probes will also trigger a flood 
transmission. 
Draft Picture 
Placement of rubber 
feet 