WellAWARE Systems Inc ZTTRX433 Benutzerhandbuch

Seite von 6
 
 
 
 
 
 
 
 
 
 
Software Protocol Info (FDT):
  
Device Type: 0x06 
Command 
Data 
 
0x01  
0x0000 
HeartBeat (once every 4 hours) 
0x02 
0x8000 
Normal Voltage è IO is High 
 
0x0000 
Low Voltage  è IO is Low 
0x03 
0x0000 
Enrolled Signal 
0x07 
0x0000 – 0x00FF 
When one of the eight bits is toggled the TRX sends the data 
0xFE 
Tx' Address 
Acknowledgement 
The "HearBeat" signal is transmitted every 4 hours when the sensor is in the idle mode. 
 
The sensor detects the voltage before transmitting RF signal.   
The "Low-Voltage" RF signal is sent when the "Low-Voltage" status is detected more than 10 times in succession.   
 
If the voltage status change from "Low-Voltage" into "Normal-Voltage", the sensor will transmit "Normal-Voltage" RF signal.