ME after performing the action. This changes the 
operational state of the ME to enable. 
•  Unlock: In this state, you cannot perform any action on 
the ME. However, there is an exception with the cell 
table. You can modify the handover and power control 
parameters in unlocked state. 
2.2.2 Operational States 
Operational state of a ME tells you the functional state of 
that ME. The change in the operational state of a ME 
depends on the internal working of BSC.  In addition, the 
operational state of ME changes only when you change its 
administrative state. You can only view the operational state 
of a ME in OMC. The states are as follows: 
•  Enabled: The ME is operable. Enabled state of a ME 
refers that it is working and communicating with the BSC. 
•  Disabled: The ME is inoperable because it is not 
installed, defective, or because of some other resource 
upon which it depends is not available (locked by 
operator or operational state is disabled due to internal 
failure). In addition, connectivity failure between the ME 
and BSS makes the ME disabled. 
2.2.2.1 Administrative Operations 
In addition to the administrative states, you can perform the 
given below operations on a ME: 
•  Reset Active: Used to restart the selected ME. 
•  Reset Stand by: Used to restart the ME, which is in 
standby mode. 
•  Connect: Used to connect a ME to a network.