Automation Controllers
ioLogik E2242
Front-end intelligence that supports 24 Click&Go™ rules
 
Active Messaging with real-time stamp, including SMS, 
 
SNMP Trap with I/O status, TCP, and email
Supports SNMPv1/v2c/v3 protocol
 
I/O peer-to-peer function
 
Built-in web console
 
PC utility: Auto detection of installed modules
 
Windows/WinCE VB/VC.NET and Linux C APIs
 
-40 to 75°C operating temperature range (T model)
 
Moxa’s ioLogik E2242 is a new type of active micro controller that 
can be used as an RTU (Remote Terminal Unit). Active Ethernet micro 
controllers are a kind of PC-based data acquisition and control device 
that use proactive, event-based reporting to control I/O devices. Unlike 
traditional RTUs, which are passive and must poll for data, Moxa’s 
Active OPC Server makes seamless connection with SCADA systems 
a reality. In addition, SNMP is used for communicating with an NMS 
(Network Management System) for IT field users. The I/O status of 
an Active Ethernet micro controller can be reported and controlled 
automatically on-site based on user specified conditions. This report-
by-exception approach, which is new to PC-based monitoring, requires 
far less bandwidth than traditional polling methods.
Active Ethernet micro controller with 4 analog inputs and 
12 configurable DIOs
Introduction
Specifications
LAN
Ethernet: 1 x 10/100 Mbps, RJ45
Protection: 1.5 KV magnetic isolation
Protocols: Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP, HTTP, 
CGI, SNTP
Serial Communication
Interface: RS-485-2w: Data+, Data-, GND
Serial Line Protection: 15 KV ESD for all signals
Serial Communication Parameters
Parity: None
Data Bits: 8
Stop Bits: 1
Flow Control: None
Baudrate: 1200 to 115200 bps
Protocol: Modbus/RTU
Analog Input
Channels: 4 analog inputs with differential input
Resolution: 16 bits
I/O Mode: Voltage / Current
Input Range: ±150 mV, 0 to 150 mV, ±500 V, 0 to 500 mV, ±5 V, 0 to 
5 V, ±10 V, 0 to 10 V, 0 to 20 mA, 4 to 20 mA
Accuracy:  
±0.1% FSR @ 25°C 
±0.3% FSR @ -10 and 60°C
Sampling Rate (all channels): 100 samples/sec
Input Impedance: 200K ohms (min.)
Built-in Resistor for Current Input: 102 ohms
DI/DO Configurable Channels
Channels: 12
I/O Mode: 
• DI or Event Counter (up to 900 Hz) 
• DO or Pulse Output (up to 100 Hz)
Digital Input
Channels: Up to 12, source/sink selectable
Sensor Type: NPN, PNP, and Dry contact
I/O Mode: DI or event counter (up to 900 Hz)
Dry Contact:  
• Logic 0: short to GND 
• Logic 1: Open
Wet Contact:
     
Common Type: 6 points per COM 
Isolation: 3K VDC or 2K Vrms
Counter/Frequency: 900 Hz, power off storage
Digital Filtering Time Interval: Software selectable
Over-voltage Protection: 36 VDC
Poweroff Counter: Supports poweroff counter storage function
DI Type
Status
Source
Sink
ON
0 to 3 VDC
10 to 30 VDC
OFF
10 to 30 VDC
0 to 3 VDC