TAIYO YUDEN CO. LTD. EYSGJN Benutzerhandbuch
17-August-2015 Ver.0.09
TAIYO YUDEN
TAIYO YUDEN
6/8
EYSGJN
Control name
Electrical characteristics
Absolute maximum ratings
Symbol
Parameter
Min.
Typ.
Max.
Units
VCC_NRF
-0.3
+3.6 V
GND
0
V
Storage temperature
-40
+125 Deg-C
Recommendation operating range
Symbol
Parameter
Min.
Typ.
Max.
Units
VCC_NRF
Supply voltage, normal mode
1.8
3.0
3.6
V
DC Specifications
The Specification applies for Topr. = 25 degrees C, VCC_NRF = 3.0V
Symbol
Parameter (condition)
Min.
Typ.
Max.
Units
VIH
Input high voltage
0.7
VCC_NRF
VCC_NRF
V
VIL
Input low voltage
GND
0.3
VCC_NRF
V
VOH
Output high voltage
VCC_NRF-0.3
VCC_NRF
V
VOL
Output low voltage
GND
0.3
V
RF Specifications
Symbol
Description
Min.
Typ.
Max.
Units
Fop
Operating frequencies
2402
2480
MHz
P
RF
Maximum output power
4
dBm
P
SENS
IT
Receiver sensitivity (0.1% BER)
Ideal transmitter
-93 dBm