Impinj Inc. XARRAY Benutzerhandbuch

Seite von 74
 
Speedway Revolution Installation and Operations Guide Octane 4.11 
 
Chapter 5: Troubleshooting 
Revision 4.11 Copyright © 2014, Impinj, Inc. 
 
31
 
 
Chapter 5: Troubleshooting 
If you experience a problem with Speedway Revolution, this brief chapter presents a few 
suggestions to correct the issue. 
Returning to the Default Configuration 
If you are experiencing a problem with the Reader and are having difficulty pinpointing the 
cause, it is useful to return the Reader to a known state. We recommend resetting to the 
default configuration. Then try your Reader again. 
!
 Important
Configuration Default Restore returns the Reader configuration to its default 
state. It leaves any custom applications installed in the CAP intact. To restore the Reader to 
its default state and remove any CAP contents, use Factory Default Restore. See the 
Warning on page 32. 
There are two ways to return Speedway Revolution to its defaults:  
1.  Issue an RShell command.  
2.  Push the Default Restore button on the device. 
To use RShell to return the Reader to its default configuration and leave CAP 
intact 
1.  At the RShell prompt, enter the following command: 
config image default 
When the command completes successfully, the Reader automatically reboots 
and returns to the login prompt. 
2.  Log in to the Reader. The Reader is now running with the default configuration. CAP 
applications are intact. 
To use the Default Restore button on the Reader to restore to its default 
configuration 
1.  Use an object with a sharp tip, such as a probe or paper clip to press and hold the 
Default Restore button on the back of the Reader while applying power to the 
Reader.  
2.  Continue holding the Default Restore button for 3 seconds after the Power LED light 
turns off, but not longer than 10 seconds.  
3.  Release the Default Restore button when the LED blinks red once. The Reader will 
boot up normally with the default configuration. 
 
 
 
 
 
 
 
 
Figure 5.1 Default Restore button 
 
Default Restore 
button 
Insert and hold sharp point here for 
3 seconds. Release before 10 
seconds.