Warning! 
1. Be sure to determine the correct wiring of the power supply polarity, wrong wiring will result in damage to the product and may endanger
2. Before setup, make sure the voltage loading of the circuit switch complies with local regulations. Improper usage of electric 
power and exceeding loading voltage will cause damage to the product. 
3. This product is a low-power RF wireless carrier communications transmission systems, in order to reduce environmental obstacles 
lead to remote insensitive, please try not to use the larger than the average residential space (details contact Dealer) 
4. If for unavoidable necessary, must do installation under electrified condition, PLS connect LINE (Black) & NEUTRAL (White), 
each to their corresponding wire first, turn off the switch, then connect the FIXTURE (Blue), & done!。 
Button/Circuit(s) Settings 
Name : 1 Circuit --- RF & Touch Control 
Model No. : LC-311S 
Power & Loading: LC-311S (AC-110V, Max. Load 1,000W) 
                
 Annex APanel Install / uninstall 
[Uninstall]
 
Put the sucker on the marked spot, press to squeeze out air 
& make sure the sucker is fixed, then pull out of the panel.
 
[Install]
 
There are 2 latches on the top of the panel, & a crystal in the 
buttom.    there is 2 slot for those 2 latches & a magnet for 
crystal. PLS make sure the direction correctly.    Slide latches 
into slots first then press the crystal side into the magnet side 
till the panel sink completely.
 
Pull!
Setting / Control
1.  PLS check Annex A to uninstall the panel.   
2.  Press & hold the Touch Sensor Area w/ your finger 
3.  Take a stick to press the Setup Button (feel a “click”), 
when the red light on, let go    your finger & setup stick. 
4.  The red light on, means the switch is under the setting mode 
(window = 10 Sec.), if not, PLS repeat step (1) & (2). 
5.  Take a remote (ex. RC-07/RC-09), select Zone (Zone 1,2 or 
3), press number (position) then press ON to send the RF 
code to the switch. 
6.  When red led blinks then turns off, it means the setting is 
completed.  PLS use the remote to control the switch 
ON/OFF, to confirm the setting. 
7.  PLS wait 30 sec. after installed the panel, till the sensor adapt 
the thickness of the panel, then you may touch the panel to 
switch ON/OFF the light.     
8. Control: 
a.) Touch sensor area to turn ON/OFF the light.      
b.) Remote: select Zone (Zone 1,2 or 3), press number 
(position) then press ON/OFF.