Airorlite Communications Inc. 50289BAX8800UL Benutzerhandbuch

Seite von 13
50289‐BA‐8‐PA
 
‐ 2 ‐
SYSTEM SPECIFICATIONS 
 
Description 
SPECIFICATIONS 
Frequency Range  
819‐824 MHz & 864‐869 MHz 
Outbound Signal ‐ Uplink (# of channels=8) 
821.2150 MHz 
  
821.8125 MHz 
(Uplink channel cards can be programmed to these frequencies only) 
822.3750 MHz 
  
822.8750 MHz 
  
823.0125 MHz 
  
823.5500 MHz 
  
823.6000 MHz 
  
823.9125 MHz 
Inbound Signal ‐ Downlink (# of channels=8) 
866.2125 MHz 
  
866.8125 MHz 
(Downlink channel cards can be programmed to these frequencies only) 
867.3750 MHz 
  
867.8750 MHz 
  
868.0125 MHz 
  
868.5500 MHz 
  
868.6000 MHz 
  
868.9125 MHz 
Channel Bandwidth (Uplink/Downlink) 
25 kHz Nominal 
Channel Spacing 
25 KHz 
RF Frequency Accuracy 
Tracks input signal exactly 
Adjacent Channel Selectivity 
70 dB @ ± 17.5 kHz Fc 
R
F Output Power (Downlink) 
~25 dBm/carrier, maximum 
RF Output Power (Uplink) 
~26 dBm/carrier, maximum
 
Variation of Output Power w/Input Level 
+0, ‐1.0 dB in either direction 
Maximum Passband Ripple Across Full Band 
2 dB 
Maximum Passband Ripple Across any 100 kHz segment 
0.1 dB 
Amplifier Input Ports (no damage) 
0 dBm 
Propagation Delay 
32 microseconds, maximum 
Intermodulation/Crossmodulation Distortion at Full Output Power 
‐60 dBc 
Channel to Channel Isolation 
‐70 dBm 
Minimum High Band Signal to produce +25 dBm output to Radiating Antenna Cable 
‐90 dBm 
Minimum Low Band Signal to produce full output 
‐90 dBm 
AGC Control Range (Uplink & Downlink) 
+80 dB 
Duty Cycle 
Continuous 
RF Spurious Output, less than 800 MHz, but greater than 1000 MHz 
‐60 dBc, Maximum 
RF Spurious Output for frequencies ranging from 800 ‐ 1000 MHz 
‐85 dBc, Maximum 
Operating Temperature Range 
‐20°C to +60°C 
System Noise Figure 
< 9 dB 
Input/Output Impedance 
50 Ohms, nominal 
Input/Output VSWR 
1.35:1, worst case 
Input/Output Connectors 
Type “N” Female 
Input Power 
95‐132 VAC, 45‐64 Hz 
Amplifiers are unconditionally stable  
under all operating conditions 
Alarm 
Loss of Power Supply, DC 
Change in current draw of +/‐ 20% for 
each internal amplifier