Advanced Card Systems Limited ACR1281S Benutzerhandbuch

Seite von 57
ACR1281S 
 
 
 Advanced Card Systems Ltd. 
Page 45 of 56 
2.5.2 Read Value Block 
The “Read Value Block command” is used for retrieving the value from the value block. This 
command is only valid for value block. 
   
Table 2.5.2-1a: Read Value Block APDU Format (5 Bytes) 
Command 
 
Class 
INS 
P1 
P2 
Le 
Read Value 
Block 
FF 
B1 
00 
Block 
Number 
00 
 
Block Number (1 Byte): 
The value block to be accessed. 
 
Table 2.5.2-1b: Read Value Block Response Format (4 + 2 Bytes) 
Response 
 
Data Out 
Result 
 
Value 
{MSB .. LSB} 
SW1 
SW2 
 
Value (4 Bytes): 
The value returned from the card. The value is a signed long integer (4 bytes).  
 
E.g. 1: Decimal  –4 = {0xFF, 0xFF, 0xFF, 0xFC} 
Value 
MSB 
 
 
LSB 
FF 
FF 
FF 
FC 
 
E.g. 2: Decimal 1 = {0x00, 0x00, 0x00, 0x01} 
Value 
MSB 
 
 
LSB 
00 
00 
00 
01 
 
 
Table 2.5.3-1c: Read Value Block Response Codes 
Results 
 
SW1 
SW2 
Meaning 
Success 
90 
00 
The operation is completed 
successfully. 
Error 
 
63 
00 
The operation is failed.