Advanced Card Systems Limited AET62 Benutzerhandbuch

Seite von 18
AET62 Design Specification 
Version 1.0  
8-DEC-09 
Page 10 of 18
 
 
 
AET62 
5.0.  Commands  for  Contact  and  Contactless  Interfaces 
Handling 
 
The  contactless  interface  is  operating  on  the  top  of  contact  interface.  Some  Pseudo  APDUs  are 
defined for contactless interface. If the reader finds that the APDUs are for contactless interface, the 
APDUs  will  be  routed  to  the  contactless  interface,  otherwise,  the  APDUs  will  be  routed  to  contact 
interface. The Contact and Contactless Interfaces are able to be operating at the same time.   
 
• 
The  Pseudo  APDU  “Direct  Transmit”  is  used  for  sending  commands  to  the 
contactless interface 
 
Command 
 
Class 
INS 
P1 
P2 
Lc 
Data In 
Direct 
Transmit 
0xFF 
0x00 
0x00 
0x00 
Number 
of Bytes 
to send 
PN532_Contactless 
Command 
 
 
2.  The  Pseudo  APDU  “Get  Response”  is  used  for  retrieving  the  responses  from  the  contactless 
interface. 
Command 
 
Class 
INS 
P1 
P2 
Le 
Get Response 
0xFF 
0xC0 
0x00 
0x00 
Number of Bytes to 
retrieve 
 
If the reader finds that the APDU is in the form of “FF 00 00 00 Lc XX XX ..” or “FF C0 00 00 Le”, the 
APDU will be routed to the contactless interface. 
 
Also,  one  Pseudo  APDU  “Bi-Color  LED  and  Buzzer  Control”  is  defined  for  controlling  the  LED  and 
Buzzer. 
 
Command 
 
Class 
INS 
P1 
P2 
Lc 
Data In 
(4 Bytes) 
Bi-Color and 
Buzzer 
LED Control 
0xFF 
0x00 
0x40 
LED 
State 
Control 
0x04 
Blinking Duration Control 
Similarly,  if  the  reader  finds  that  the  APDU  is  in  the  form  of  “FF  00  40  XX  04  XX  XX  XX  XX”,  the 
APDU will be used for setting the LED and Buzzer State. 
 
The  contact  interface  must  be  activated  in  order  to  send  commands  to  the  contactless  or  LED 
interface.