Advanced Card Systems Limited AET62 Benutzerhandbuch

Seite von 18
AET62 Design Specification 
Version 1.0  
8-DEC-09 
Page 7 of 18
 
 
 
AET62 
4.0. HARDWARE INTERFACES 
4.1. Power Supply 
The AET62 requires a voltage of 5V DC, 150mA regulated power supply, and gets the power supply 
from PC. 
 
4.2. USB Interface 
The AET62 is connected to a computer through USB as specified in the USB Specification 1.1.  The 
AET62 is working in Full speed mode, i.e. 12 Mbps. 
 
 
 
 
 
 
 
4.2.1. 
Endpoints 
The AET62  uses the following endpoints to communicate with the host computer: 
4.2.1.1. 
Smart Card Reader 
 
Control Endpoint 
For setup and control purpose 
Bulk OUT 
For command to sent from host to AET62 (data packet size is 64 bytes) 
Bulk IN 
For response to sent from AET62 to host (data packet size is 64 bytes) 
Interrupt IN 
For card status message to sent from AET62 to host (data packet size is 8 
bytes) 
 
4.2.1.2. 
Finger Print Device 
Control Endpoint 
For setup and control purpose 
Bulk OUT 
For command to sent from host to Device (data packet size is 64 bytes) 
Bulk IN 
For response to sent from Device to host (data packet size is 64 bytes) 
 
Pin 
Signal 
Function 
V
BUS
 
+5V power supply for the reader (Max 200mA, Normal 100mA) 
D- 
Differential signal transmits data between AET62 and PC. 
D+ 
Differential signal transmits data between AET62 and PC. 
GND 
Reference voltage level for power supply