Arcadian Networks Inc. AE11OW Benutzerhandbuch

Seite von 22
 
 
- 4 -
  
AE11GOW WMU User’s Guide 
Installation and Safety Information 
The following information is provided to ensure safe operation of this equipment. 
Arcadian Networks assumes no liability in the event that the customer fails to 
comply with the following safety precautions and warnings. 
DC System Power-on 
1- When connecting the DC power lines, make sure to connect the Ground line 
first. 
2- When disconnecting the DC power lines, make sure to disconnect Ground 
last. 
3- FUSE Replacement: Make sure to use a fuse of the same type and value! 
4- EUT shall be powered from limited power source up to 100VA according UL 
60950-1 requirements. 
L’équipement sous tension doit être branché a une source limitée au maximum  
de100 VA conformément a UL 60950-1. 
5- Voltage rating is 12 VDC 
La tension d’opération est à 12 VDC.  
Earthing 
The minimum cross sectional area of the protective earthing should be 1mm
2
La section du fil de terre doit être d’un minimum 1mm
2. 
 
Cables 
The power, Ethernet and RS232 cables shall be limited up to 140 Feet (42.6 
meter). 
Les branchements électriques, Ethernet & RS232 doivent être limités a un 
maximum de 140 pieds (42.6 mètres)  
Repair Safety 
Repairs of modem should take place only in Arcadian Networks service 
laboratories or in service laboratories of other Arcadian Networks formally 
approved distributors.  
 
In case of field handling, disconnect the unit from power supply for safest repair.