3 Installing the V390i 
16 
V290iA User Guide 
Prerequisites to Installation 
Before installing the V390i: 
1.  Make sure the UHF antenna is installed and adjusted towards the relevant Base 
Station. 
2.  Check the installation environment to ensure compliance with the following 
requirements: 
„ 
Install the V390i indoors, not open to the elements. 
„ 
Install the V390i so that air can flow around the heat sink fins, therefore do not 
install it in a small closed confined space. 
„ 
Operating temperature: -22°F to +158°F, -30°C to +60°C. 
„ 
Storage temperature: 40°F to +185°F, -40°C to +85°C. 
„ 
Relative humidity: 55% average (non-condensing), 95% for 96 hours (non-
condensing). 
3.  If you are mounting the V390i on a wall or pole, make sure they can carry 20 kg. 
4.  Check the installation infrastructure and make sure you have the following cables: 
„ 
Power cable with fuse. The requirements for the power inlet matching connector 
include: 
•  Cable – CABLE SHIELDED 4 X 22AWG. 
•  Plug sealed – Manufactured by Tyco, MFG: 796094-2. 
•  Pin – Sock pins 15u gold 16-18awg, manufactured by Tyco, MFG: 66101-3. 
•  Boot #11 – Manufactured by Tyco, MFG: 207489-1. 
•  This connector is the same as the one used for the Cisco 3230. 
„ 
Ground wire with soldier lug, according to the following specifications: 
•  Inner STUD Size: AWG ¼, 6.4 mm. 
•  Terminal material: Copper. 
•  Wire range: AWG 14 to 16, 1.5 to 2.5 mm
2
•  Max electric current: 27 Amp. 
„ 
UHF Antenna cable. To achieve maximum coverage in distant or NLOS 
locations, use low loss cables (loss below 2 dB) between the V390i and the 
antenna. Typical low loss cables are: 
•  LMR900 – Loss 1.1 dB/100 feet @ 770 MHz. 
•  7/8 HELIAX – Loss 1.1 dB/100 feet @ 770 MHz. 
•  1/2 HELIAX – Loss 1.8 dB/100 feet @ 770 MHz). 
5.  Provision the V390i in the NMS (refer to the NMS User Guide). You need the 
V390i’s MAC address, which is displayed on the V390i label, as shown in Figure 5.