3.3 
Connecting of the power supply cable 
The reader has to be supplied with 9..30V DC. The maximum output power of the power supply has to be 
1.2 Watt. Be sure that you use the right polarity. 
3.3.1  Using the pc connection cable ID 70213 
Power supply:   
brown = 
+ 9 .. 30 Volt 
 
 
 
white =  
ground 
3.3.2  Using the switchboard cable ID 70212 
Power supply:   
brown = 
+ 9 .. 30 Volt 
 
 
 
white =  
ground 
 
Data interface:  
green =  
RXD (readers data input) 
 
 
 
yellow = 
TXD (readers data output) 
 
 
 
grey =   
ground 
3.3.3  Using a self assembled connecting cable 
Using the following SAB cabs you can assemble your own connecting cable. 
 
ID 70211 
SAB cab with 1 PG9 cable pipe 
ID 70215 
SAB cab with 2 pre-assembled cable pipes 
ID 70219 
SAB cab without any cable pipe 
 
You can use any shielded five-pole cable. The allowed diameter of the cable must be in the range from  
∅3,5 to ∅8mm. For this case, IP 65 is reached.