Installation and User Instructions for S813 Enrollment Readers
The S813 Enrollment Reader is used to capture
fingerprints, and to encode Philips
Philips
S813
®
®
MIFARE or
MIFARE DESFire contactless smart cards.
The
connects to a serial port of a controlling
Security Management System (SMS) PC using the
supplied cable.
Insert the jack plug
into the socket on
the back of the
reader bracket.
Insert the power
plug into the socket
on the back of the
reader bracket.
Connect the 12Vdc
power source to the
mains supply.
Connect to a serial port
of a PC installed with the
SMS software. Set up the
port in the Install/Client
Ports screen of the SMS
software.
To use the enrollment reader:
1. Log in to the SMS software at the PC that the reader is connected to.
2. Start the fingerprint enrollment procedure from the
. Follow the prompts.
3. Start the encoding procedure from the
Fingerprint Enrollment screen, accessed
through the Badge tab of the Card Holders screen
Fingerprint Enrollment screen. When prompted, present
the card to be encoded under the finger pad of the reader (tabs are provided on the base plate
if you prefer to rest the card against the reader). You will hear a "bleep" when the card has
been encoded.
Note: Refer to the enrollment guidelines overleaf.
4
Enrollment Procedure
2
Reader Connections
1
Installation
This illustration shows the
connections from the reader to
the RS232-to-RS485 converter
and power supply. There should
be no need to make these
connections yourself - use the
supplied cables.
S813 Reader TB1
XMT
-
G
XMT+
RS232-to-RS485
Converter
0V
0V
TX+
TX-
I/0
Do
not
use
RX+
RX-
+12V
12V
Twisted pair
Note the apparent reverse in
polarity between the converter
and reader (from "-" to "+" and
vice versa)
12Vdc power
3
Reader Links and Switches
The following links are provided on the reader's PCB:
LK1
(Audio feedback) - Set to "0" for sound off. Set to "1" for sound on.
LK2
(TERM) - Ensure that this link has been removed.
LK3
(TEST) - Ensure that this link has been removed.
Ensure that all bit switches in SW2 (RDR ADDR) are set to the OFF position.