La Crosse Technology M-12 Benutzerhandbuch

Seite von 2
 
1
Solar Panel 
    
    
    
    
    
    
TX
TX
TX
TX----63
63
63
63U
U
U
U----IT
IT
IT
IT        
SOLAR WIND SENSOR
SOLAR WIND SENSOR
SOLAR WIND SENSOR
SOLAR WIND SENSOR    
 
The TX63U-IT Solar Wind sensor is used in conjunction with the TX59U-IT relay 
transmitter to gather and transmit information to the wireless Weather Station 
(e.g. WS-2812U-IT).  
 
INVENTORY OF CONTENTS
INVENTORY OF CONTENTS
INVENTORY OF CONTENTS
INVENTORY OF CONTENTS    
1. 
TX-63U-IT Solar Wind sensor 
2. 
One Plastic reset rod. 
3. 
Mounting bracket 
4. 
Mounting hardware 
5. 
Instruction manual 
 
 
 
 
 
 
 
 
 
 
START THE SOLAR WIND SENSOR
START THE SOLAR WIND SENSOR
START THE SOLAR WIND SENSOR
START THE SOLAR WIND SENSOR    
During the first time of operation, user has to remove the mask that covered on 
the solar panel then gently press the RESET button once in the bottom of the 
device by the provided Plastic reset rod 
to wake it up. 
 
Note:
 It is important to allow sufficient 
light to reach the solar panel while 
activating the Solar Wind sensor. Make 
sure the lights are on in the setup room 
and the solar panel is facing a 60W 
light bulb or brighter – do not cover 
with hands or other objects. 
 
IDLE MODE
IDLE MODE
IDLE MODE
IDLE MODE
 
This mode aims to reduce power consumption of the transmitter. Under this 
mode, the sensor stops the transmission of signal, checks the battery voltage 
and detects the solar cell condition. The IDLE mode happens if the battery 
voltage is low. 
 
Note:
 The sensor will check and charge up the internal rechargeable battery 
automatically, when it detects the battery voltage raises up to sufficiently high 
enough, the transmission of signal starts again. 
 
STOP MODE 
STOP MODE 
STOP MODE 
STOP MODE 
 
It is the most energy saving mode. Under this mode, the transmitter stops the 
transmission of signal, no checking battery voltage, no detecting the solar cell 
condition and force it stop charge batteries. The STOP mode happens: 
 
• 
If the user covers the solar cell for 10 seconds and presses the RESET 
button.  
Note:
 To restart the Solar Wind sensor, user should place the sensor in a 
bright environment then press the RESET button once to wake it up again.  
 
• 
If the sensor is placed in the dark environment for 72 hours. 
Note:
 To restart the Solar Wind sensor, user should move the wind cup or 
place the sensor in a bright environment then press the RESET button 
once to wake it up again.  
 
IMPORTANT! During the restart process, if the battery voltage is sufficiently 
high enough, the transmission of signal starts again. However, if the battery 
voltage is low, the sensor enters into IDLE mode. User should place the sensor 
under a bright environment in order to charge up the rechargeable batteries 
inside the sensor. 
 
SETTING UP
SETTING UP
SETTING UP
SETTING UP    
Follow the setup process below to make sure this device can work properly with 
the wireless weather system:  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. 
All sensors should be ready for the setup process. First, insert batteries to 
the Rain sensor, and then switch on the Solar Wind sensor by pressing its 
RESET button. Finally, insert batteries to the Thermo-Hygro sensor. 
IMPORTANT! Make sure the correct polarity when inserting batteries. 
Inserting the batteries incorrectly may result in permanent damage to the 
units. Only use alkaline batteries, rechargeable batteries may not work. 
2. 
Insert batteries into the Weather Station, e.g. the model WS-2812U-IT. 
Note:
 During the setup process, place the wireless display and the 
outdoor sensors on a surface with 3-10 feet between the sensors and the 
display. 
3. 
The Weather Station receives data from the Thermo-Hygro sensor. The 
collected information should be displayed on the Weather Station, 
including the outdoor temperature, humidity, rainfall, wind-chill and wind-
speed and wind-direction. 
Note:
 Every time the Weather Station receives data from the sensors, the 
wireless icons 
 will blink once and then return to solid if the last 
transmission was successful. A wind speed or rainfall amount that reads 
"0" does not mean reception failure, it means that there was no wind or 
rain at the time of the last measurement. If the sensor data fails to display 
for any of the outdoor sensors within 10 minutes, (“- - -“ is displayed), 
Remove the batteries from all units for 1 minute and start again from step 
1. 
4. 
You may then check all components for correct function by manually 
turning the wind-gauge, moving the weather-vane, tilting the rain sensor to 
hear the impact of the internally moving seesaw, etc. 
5. 
Time and date shall be manually set for the Weather Station. 
6. 
After the Weather Station has been checked for correct function with 
regard to the above points, the initial set up of the wireless weather 
system is finished and the mounting of the system components can take 
place. 
Note:
 The Weather Station and the Thermo-Hygro sensor should be set 
within the reception distance (up to 200 feet / 60 meters in open space). 
The Thermo-Hygro sensor and the Rain sensor should be set within the 
reception distance (up to 200 feet / 60 meters in open space). The 
Thermo-Hygro sensor and the Solar wind sensor should be set within the 
reception distance (up to 330 feet / 100 meters in open space). The Rain 
sensor and the Solar Wind sensor should be mounted on the same side of 
the house provided there are no interfering obstacles such as buildings, 
trees, vehicles, high voltage lines, Ham radio antennae, etc. Radio 
interferences created by PC screens, cordless phones, radios or TV sets 
can in some cases entirely cut off radio communication. Please take this 
into consideration when choosing standing or mounting locations. 
Detailed setup procedures of the wireless weather system, refer to the 
main operation manual of the Weather Station. 
 
MOUNTING
MOUNTING
MOUNTING
MOUNTING    
The Solar Wind sensor must be installed with the solar panel facing true South, 
or the reported wind direction will not be accurate. This device should be 
mounted within the reception distance (up to 330 feet / 100 meters in open 
space) of the Thermo-Hygro sensor and on the same side of the house. Mount 
at least 3 feet above the roofline of your house. Please be sure there is clear 
area in every direction from buildings, trees, hills etc. 
 
Mount the wind sensor onto a mast so the wind can reach the sensor 
unobstructed from all directions for an accurate reading. The ideal mast is 
between 0.62” and 1.3” in diameter. Secure the main unit to the shaft of the 
mast holder. Use the right-angle adapter if the wind sensor will be mounted on a 
horizontal mast or surface. 
 
The remote wind speed sensor can be mounted two ways: 
• 
Using nylon straps  
• 
With the use of screws 
 
 
 
 
 
 
 
 
 
 
 
 
 
MOUNTING WITH NYLON STRAPS
 
1. 
Place two nylon straps through the slots on the mounting bracket. 
2. 
Place the Solar Wind sensor in your desired location. 
3. 
Fasten the two nylon straps securely around the mounting location. 
4. 
Slide the Solar Wind sensor onto the bracket making sure to lock it in 
place. 
 
MOUNTING WITH SCREWS 
1. 
Place the mounting bracket over the desired location. 
2. 
Through the two screw holes of the bracket, mark the mounting surface 
with a pencil. 
3. 
Screw the mounting bracket and right-angle adapter onto the mounting 
surface.  Ensure that the screws are tight against the bracket, but do 
not over-tighten the screws, or the mast holder may break. 
4. 
Slide the Solar Wind sensor onto the bracket. Make sure to lock it in 
place. 
Wind vane 
Fixed with 
screw 
Right-angle 
adapter 
Wind cup
TX63U-IT 
RESET 
button 
Bottom of the Solar 
Wind sensor 
Vertical mast 
Fixed with 
Nylon strap 
330 foot 
Range