Baumer Electric AG OIS-W-WR300303 Benutzerhandbuch
Baumer Ident AG
21 / 22
Author: Clemens Zehnder
File: Maintenance-SW.doc Version 3.0 e
Range DelayRange
[m] [bin]
1 1
2 2
3 2
4 3
5 3
6 4
7 4
8 5
9 5
10 6
Table 4-5: DelayRange
Example:
If you want to cover the following reading range:
•
Ant 1:
2m
•
Ant 2:
5m
Set the following values:
⇒
DelayRange1: 2
⇒
DelayRange2: 3
Ant
There are three possibilities::
•
Ant=0
both antennas are alternatively active
•
Ant=1
only antenna 1 is active
•
Ant=2
only antenna 2 is active
Please note that in triggered mode the trigger event has a higher priority than the parameter „Ant“. This
means that if antenna 2 is triggered at parameter settings „Ant = 1“, antenna 2 nevertheless starts a
decoding.
means that if antenna 2 is triggered at parameter settings „Ant = 1“, antenna 2 nevertheless starts a
decoding.
Channel
This parameter defines the starting frequency of the ramp in order to adapt it to the tag medium
frequency.
frequency.
Parameter Start-frequency
2 2402
MHz
3 2403
MHz
... ...
30 2430
MHz
picture 4-3: channel
AFAGC
This parameter defines the NF AGC attenuation. Normally it is the best way to set this parameter at „0“,
that means that NF AGC works automatically.
that means that NF AGC works automatically.
Nnoisebin
This parameter defines the number of Bins used for noise average left and right from reflector slot.