Baumer Electric AG OIS-W-WR300303 Benutzerhandbuch

Seite von 74
Baumer Ident AG 
 
21 / 22 
 
Author: Clemens Zehnder   
 
File: Maintenance-SW.doc Version 3.0 e     
 
 
Range  DelayRange 
[m] [bin] 
1 1 
2 2 
3 2 
4 3 
5 3 
6 4 
7 4 
8 5 
9 5 
10 6 
Table 4-5: DelayRange 
Example: 
If you want to cover the following reading range: 
• 
Ant 1:  
2m 
 
• 
Ant 2:  
5m 
Set the following values: 
⇒ 
DelayRange1: 2 
⇒ 
DelayRange2: 3 
Ant 
There are three possibilities:: 
• 
Ant=0 
both antennas are alternatively active 
• 
Ant=1 
only antenna 1 is active 
• 
Ant=2 
only antenna 2 is active 
Please note that in triggered mode the trigger event has a higher priority than the parameter „Ant“. This 
means that if antenna 2 is triggered at parameter settings „Ant = 1“, antenna 2 nevertheless starts a 
decoding.  
Channel 
This parameter defines the starting frequency of the ramp in order to adapt it to the tag medium 
frequency. 
 
Parameter  Start-frequency 
2 2402 
MHz 
3 2403 
MHz 
... ... 
30 2430 
MHz 
picture 4-3: channel 
AFAGC 
This parameter defines the NF AGC attenuation. Normally it is the best way to set this parameter at „0“, 
that means that NF AGC works automatically.  
Nnoisebin 
This parameter defines the number of Bins used for noise average left and right from reflector slot.