Intel P4304BTSSFCN Benutzerhandbuch

Seite von 20
Monthly Specification Update 
Enterprise Platforms and Services Marketing 
 
 
4. 
Intelligent Platform Management Bus (IPMB) functions on devices 
connected to IPMB connector might not be available on Intel
®
 Server 
Board S1200BTL 
Problem 
Intelligent Platform Management Bus (IPMB) functions on devices connected to 
IPMB connector might not be available on the Intel
®
 Server Board S1200BTL. 
Implication 
The issue has been root caused to a violation of IPMI and PM Bus specification 
on the IPMB and PM Bus ports. 
Status 
This issue is fixed in BMC Revision 01.05. 
Workaround 
None. 
5. 
Unable to install Linux SLES* 11 Service Package 1 to iSCSi drive from 
onboard Intel
®
 82579 network card 
Problem 
Unable to install SLES11* SP1 to iSCSi drive from 82579 network card. 
Implication 
SLES11* SP1 doesn’t include a driver for Intel
®
 82579 network cards. 
Status 
The issue is under investigation. 
Workaround 
N/A. 
6. 
Node Manager does not work with Intel
®
 Core™ Processor i3-2100 series 
or Intel
®
 Pentium
®
 Processor 
Problem 
On Intel
®
 Server Board S1200BTL, node manager is supported with Intel
®
 
Xeon
®
 Processor E3-1200 Series, but node manager is not supported with 
Intel
®
 Core™ Processor i3-2100 series or Intel
®
 Pentium
®
 Processor. 
Implication 
Hardware required for CPU power limiting is functional on Intel
®
 Xeon
®
 
Processor; it is not functional on Intel
®
 Core™ i3 processor or Intel
®
 Pentium
®
 
Processor. 
Status 
No Fix. 
Workaround 
N/A. 
7. 
Intel
®
 
Integrated RAID Module SRMS2LL040 doesn’t work 
Problem 
OS is installed to the Intel
® 
Integrated RAID module SRMS2LL040 with SATA 
CDROM (the on-board SATA mode is set to AHCI mode in BIOS Setup), the 
OS fails to reboot after removing CDROM. 
Implication 
The OpROM of SRMS2LL040 is not compatible with the BIOS.