Contec FXE3000-US Benutzerhandbuch

Seite von 2
 
 
 
 
1
 
FXE3000-US 
IEEE802.11n/a/b/g Wireless LAN   
Access Point Board 
FXE3000-US Setup Guide 
CONTEC CO., LTD.
 
The FXE3000-US is a wireless LAN board that conforms to IEEE 802.11n/a/b/g standards of various 
countries and features a wide input power supply (5 to 30 VDC) and can be configured either as an 
access point or station. 
Packing List 
- Main unit (FXE3000-US)...1 
- Setup Guide...1 
Default setting 
This product is set up via a network using a Web 
browser. Connect this product to the PC with a 
LAN cable using the wired LAN connection and 
then access the default IP address in a web 
browser. This product's default settings are shown 
in the table to the right. 
Setting Item 
Default setting 
IP Address 
192.168.0.1 
Subnet Mask 
255.255.255.0 
ESSID 
LocalGroup 
Security 
Disable 
Username 
admin 
Password 
pass 
Component Locations 
 
(1)  LAN port 
(2)  Power connector 
 
(3)  DC JACK 
(4)  INIT connector 
 
(5)  DIP Switches 
(6)  DIP LED 
 
 
LED display 
LED name 
Status 
Indicator 
POWER 
ON 
Indicates that the device is operating. 
Flashing 
Indicates that the device is being started (This device turned on) 
OFF 
Indicates that the device is power off. 
LAN 
ON 
Indicates that a wired LAN has been connected. 
Flashing 
Indicates that the product is transmitting/receiving data to/from 
the connected terminal through wired LAN. 
OFF 
Indicates that a wired LAN not logged-in. 
WLAN 
ON 
Indicates that the device has been connected. 
Flashing 
Indicates data is being transmitted to or received from the device 
connected through wireless LAN. 
OFF 
Indicates that the device has been no connected. 
POWER/ LAN/ WLAN 
Flashing (simultaneously)  Indicates that firmware has been reprogrammed. *1 
POWER/LAN 
Blinking twice / On 
DHCP error 
*1 Not include LogFile 
DIP switches
 
   
INIT connector
 
No.  Name 
Operation / function 
    No. 
Name 
Operation / function 
INIT  Turning on this switch flashes the POWER, 
WLAN LEDs.If the switch is turned off before 
the LEDs change their status from flashing to 
ON (about 3 seconds), all the settings are 
restored to the default settings after the 
product is started next time. Reboot the 
product after the LEDs stop flashing. *1 
   
INIT 
Short the INIT signal with the GND so 
that the POWER, WLAN, and LAN LEDs 
will flash. Then if you open the INIT signal 
before the LEDs turn on (approx. 3 
seconds), the settings are restored to the 
default settings the next time the product 
is started. 
 
   
GND 
GND 
Pin header (JP2) 
 
 
 
LAN connector 
 
No. 
Name 
Operation / function 
 
 
No. 
Name 
Operation / function 
LAN port 
4pin 
The INIT (initialization) signal can be 
connected to via pin 4 on the LAN port 
by shorting pin 1 and pin 2. 
 
 
1  TX+ 
Transmit (+) 
 
 
2  TX- 
Transmit (-) 
2  INIT 
 
 
3  RX+ 
Receive (+) 
3  LAN port 
5pin 
The GND can be connected to via pin 5 
on the LAN port by shorting pin 3 and 
pin 4. 
 
 
4  INIT/NC 
Short the INIT signal with the GND so 
that the POWER, WLAN, and LAN LEDs 
will flash. Then if you open the INIT signal 
before the LEDs turn on (approx. 3 
seconds), the settings are restored to the 
default settings the next time the product 
is started.*1 
* Usable when JP2 No. 1 and No. 2 are 
connected. 
 
 
4  GND 
 
 
LAN port 
7pin 
The power supply line can be connected 
to via pin 7 on the LAN port by shorting 
pin 5 and pin 6. 
 
 
 
 
6  24VDC 
 
 
LAN port 
8pin 
The GND can be connected to via pin 8 
on the LAN port by shorting pin 7 and 
pin 8. 
 
 
5  GND 
GND 
 
 
6  RX- 
Receive (-)
 
8  GND 
 
 
7  24VDC 
Power Supply 
 
 
 
 
 
8  GND 
GND 
*1    Usable when JP2 No. 1 and No. 2 are connected. When initializing the product by turning the INIT signal on and off, the LEDs will continue 
flashing for a short time after the signal is turned off. This indicates the internal memory files are being deleted. If the power is turned off while the 
LEDs are flashing, the internal memory files may be damaged and the product may no longer be able to start properly. Always restart the product 
after the LEDs stop flashing.
 
 
 
 
When supplying power via the LAN connector, do not use a combination of power supplied from the power connector and the AC 
adapter. 
-  For PoE wire route only in the same building 
 
Power Supply 
Using the DC JACK 
The power plug to be used must conform to EIAJ voltage classification 2. 
 
 
When supplying power via the LAN connector, do not use a combination of power 
supplied from the power connector and the AC adapter. 
 
 
Using the Power connector 
The power connector in Figure 1 can be used to 
supply power from an external source. Use the 
following power cable or its equivalent. 
 
 
When supplying power from the power connector, 
do not use a combination of power supplied via the 
LAN connector and the AC adapter. 
 
 
Power connector
 
Housing: JST S02B-PASK-2(LF)(SN) 
Cable: AWG28-16(equivalent to it)
 
Pin No.
 
Nome 
Operation / function 
 
1
 
Vi+
 
5-30VDC
±
5%)
 
2
 
Vi-
 
GND
 
When supplying the LAN cable power 
 
-  Create the power cable correctly as specified. Using the power cable with the 
housing pins assigned wrong numbers may result in device faults or accidents. 
-  The input voltage range of this product is from 5 to 24 VDC ±5%. Supply 
power outside that range may result in device faults or accidents. 
-  Use the power supply whose supply voltage rises to at least 4.75VDC within the 
input voltage range within 10ms. Using a power supply which does not satisfy 
this condition may result in device faults or accidents. 
-  Input voltage range: 5 to 30 VDC ± 5%. Use a power supply that rises to 4.75 
VDC or higher in the input voltage range within 10 ms. There is a risk of 
damage to the device or accident if a power supply outside this range is used. 
 
 
 
Installation 
Read and understand the following precautions before installation : 
-  Leaving a metal object in the vicinity of 30mm from the antenna board affects the antenna characteristics.   
Do not place metal objects near the antenna as possible. 
-  This product has a protrusion of up to 14mm on the front surface and a protrusion of up to 3mm on the rear surface. Allow 
clearance around this product and use it within the range of ambient temperatures satisfying the environment conditions for 
installation. 
-  Figure 2 shows the locations the mounting holes for installing this product and external dimensions. 
-  Use M3 screws for the mounting holes (
φ
2.3 mm). 
-  The lower right mounting hole is the FGND (grounding) hole. Connect it to FGND (ground).
 
* 1 Always reboot the product after the flashing stops. The flashing continues for a little while after the product is switched off during 
initialization by switching on and off the INIT switch. This indicates internal memory files are being deleted. The internal 
memory files may be damaged and the product may not start up properly if the power is switched off before the flashing stops. 
 
Connecting to This Product Using Web Browser 
Start up a Web browser and enter the IP address of this product after “http: //” in the address bar. If 
connecting for the first time, enter the default IP address. When the default setting IP address is 
192.168.0.1, enter as follows. 
http://192.168.0.1/   
Connecting to this product displays the “Wireless LAN 
Manager” login screen/ If the login screen is not displayed, 
the IP address setting for PC, browser settings, or the URL 
entered in the address bar of the browser may be incorrect. 
 
Enter a password on the login screen and then click “Login” to log in. 
When connecting for the first time, Default setting is Username=”admin” & Password=”pass” and just 
click “OK” . 
If the login is successful, the following setup screen will be displayed after a little while. 
Setup Using Web Browser 
Select the desired setting items from the opened menu (1). 
Information such as setting items will be displayed in the 
right-hand frame. 
For more information about a setting item, please refer to 
"help" (2). 
Click “Submit” (3) after changing settings on each page to 
temporarily save the settings in this product. 
The settings become enabled when the product is restarted 
after all the setup procedure is completed and the settings 
are stored. Click “Save & Reboot” (4) on the left-hand 
menu. 
 
There will be no problem if you just save the settings now but reboot the product later when necessary. 
In this case, saving the settings does not actually change the settings of the product. Therefore, make 
sure to reboot the product later 
 
 
  It takes approximately 5 - 10 seconds to save settings (writing to internal flash memory). During that period, 
the LEDs for POWER, LAN and WLAN at the front part of the main unit blink simultaneously. Do not reboot 
or turn off the product until the screen indicates the completion of the saving process. The setup file data and 
firmware data may be damaged and the product may not operate properly if it is rebooted or switched off 
during the saving process. 
Safety Information 
This document provides safety information using the following symbols to prevent accidents resulting in injury or 
death and the destruction of equipment and resources. Understand the meanings of these labels to operate the 
equipment safely.   
 
 
  DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious 
injury. 
 
 
 
  CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate 
injury or in property damage. 
 
WLAN
POWER
LAN
C A U T IO N
C A U T IO N
C A U T IO N
C A U T IO N
C A U T IO N
D A N G E R
C A U T IO N