BM210012WT37 
Server Initialisation 
The port server must be running for the Client applications to work. 
‘PortServer.exe’ takes the desired serial port name as a command line 
parameter. If no command line parameter is specified, ‘PortServer’ 
assumes that ‘com1’ is desired. Start the server application by running 
‘PortServer.exe’. If com2 is connected to the modem, run the server as 
following: PortServer com2.  
This server application does not have a user’s interface. The only way 
to ensure that it is running is to view the active processes on the 
Windows Task Manager.  
VDD Library 
The VDD library contains all tools required for client-server 
communications by using the MSMQ service to deliver messages to the 
other party. All client applications are required to open a session with 
the server application if it wants to communicate with the modem. By 
using the VDD library this process message delivery is transparent for 
the client.  
 
Please refer to Appendix B – SDK NCL-API and Port Server and 
Appendix C – SDK Sample programs for additional information on the 
Boomer II SDK contents.