RadioFrame Networks Inc MCSERIESHP10 Benutzerhandbuch
Final Checkout and Commissioning
MC-Series High-Power System
998--01
Rev
X1
50
CONFIDENTIAL AND PROPRIETARY
RadioFrame Networks, Inc.
TRADE SECRET INFORMATION
• Initial power
• System setup
• System verification
• Functionality test
• System setup
• System verification
• Functionality test
5.1 Prerequisites
Ensure that the following has taken place:
• The T1 is live and has been tested
• The datafill has been completed, including BR cabinet and position assignments,
• The datafill has been completed, including BR cabinet and position assignments,
and conforms to the recommended datafill shown in section 6.1.3 “Recommended
Datafill Parameters”
Datafill Parameters”
• Site configuration is available
• All cabling and installation work has been completed and all punchlist items
• All cabling and installation work has been completed and all punchlist items
corrected
Required Tools:
• R2660 Series Communication System Analyzer
• Digital RF meter
• Laptop computer to bring up the MC-Series system. At a minimum, the laptop must
• Digital RF meter
• Laptop computer to bring up the MC-Series system. At a minimum, the laptop must
be loaded with the following fully functional equipment (or equivalent):
Pentium II / 233 MHz (Pentium III / 500 MHz recommended, or better)
128 MB of memory (256 MB recommended)
10 GB hard drive (64 MB disk drive space minimum available for software)
12x (or faster) CD-ROM (USB memory stick with 64 MB recommended)
Windows 98 (Windows 2000 Professional or better recommended)
Internet Explorer 5.5 or later (not Mozilla Firefox)
• One Ethernet port and one 9-pin serial port
• 6-foot Cat-5 (or 5e/6) Ethernet cable (EIA/TIA 568B) to connect to the BIC CRIC
• Straight-through, male-to-female serial cable (DB9/RS232)
• 50 Ω terminating loads for all RF ports to be used according to the site configuration
• 6-foot Cat-5 (or 5e/6) Ethernet cable (EIA/TIA 568B) to connect to the BIC CRIC
• Straight-through, male-to-female serial cable (DB9/RS232)
• 50 Ω terminating loads for all RF ports to be used according to the site configuration
Ensure that the following RadioFrame Networks software is available:
• CD ROM (backup)
• New versions can also be downloaded from RFN web site to the local root directory
• New versions can also be downloaded from RFN web site to the local root directory
(C:/)
For local software downloads, have the following available on the laptop:
• FTP server software—WFTPD32 is shareware that can be downloaded from the
following site: http://www.wftpd.com/
• Terminal emulation software (e.g., PROCOM)