USER MANUAL FOR COMFLEX 6100 1W 
 
ENU STATUS : 1-0-0 
Copyright - refer to title page 
Page 41 
 
 
 
 
 
 
Figure 44: RU Device 
 
NOTE: There are three statuses for PA Service: NormalRecovery and Shutdown. If PA output power 
or reflected power exceeds the threshold (32dBm), software will trigger Recovery:  
 
It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA 
Service Status will turn to Normal, if PA output power or reflected power is still over the threshold, PA 
Service Status will turn to Recovery again. 
 
If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA 
Service status will be Shutdown which will need to be reset manually. Reset at Management > PA 
Reset. 
 
Click on a specific band on the left side of RU Device page, the corresponding band information will show. 
 
 
Figure 45: RU Device 
– 700