WebGate Inc. WB101X-WG1K Benutzerhandbuch

Seite von 30
 
 
WebEye 
WebEye  B101
B101 User’s Guide 
24 
menu, Administrator may set quality level of unfocused area in the image (out of the focused range).   
• 
Image Quality Level: Administrator chooses image quality level from 0 to 9. If level 9 is chosen, 
WebEye sends the finest image. However, transmission speed will be reduced because of larger sized data. 
The  image level inside the ‘QBOX ’ is the same level as is selected in this menu. 
 
8) Application Configuration 
This page is to configure e -mail and file sending 
function. 
 
(1) Recipient E-mail Address 
This is to designate a person to receive E-mail.   
 
(2) Sender’s E-mail Address 
This is to put a person ’s e-mail address that is 
considered as the e-mail sender.   
 
The e-mail sender can be a person who should 
take care of the situation when events occur. 
E-mail will be delivered to a person who is 
defined as a recipient in the blank of  ‘E-Mail 
Recipient ’. The person who received e-mail can 
send a message of countermove to a person who 
is defined as an e-mail sender.   
 
(3) Check E-Mail Options 
Relay Mail Server
: With the same problem of e-mail blocking, WebEye has  a function to relay its e -mail 
through an available e-mail server so that e -mail can have the relay server’s domain name. After activating 
‘User Relay Mail Server ’ menu, you key in a server’s domain name such as ‘@abcdefg.com’.   
 
Content-Transfer-Type: It is to define e-mail format. E-mail servers support ‘Base64’ format in common, 
but some servers not. In the case, you may select the format as ‘Quoted Printable ’. 
 
(4) E-Mail Event Configuration 
Event source : Administrator should define with which event E-mail is to be delivered among MD (motion 
detection), sensor 1, sensor 2, sensor3, and sensor 4. If administrator clicks on sensor1, e-mail is sent when 
the sensor1 detects events. (To utilize sensor input detection, a sensor should be connected to WebEye.)   
 
File name : With the images of MD and Sensor event, a file is named combining all options. And with the 
image of periodic sending event, administrator may decide how to name image files among three methods. 
Administrator names a file with data & time (DATETIME; E.g IMG-CH00-2001030-223031.eye) or serial 
number (SEQNUM; E.g. IMG-CH00-SN1.eye). The image file has its extension of ‘eye ’ so that the file is to 
be reproduced on Internet browser.   
 
Image quality: Administrator may set image ’s resolution that is delivered by e-mail. Resolution is to be set 
among 90x60, 180x121, 360x243, 720x243, and 720x486. An image of 90 by 60 is of the lowest resolution 
and the smallest size.   
 
(5) FTP directory configuration