Opticon Sensors Europe BV PX20 Benutzerhandbuch
9
Opticon
PX-20
Specifications Manual
6.3. Electrical Characteristics
Parameter
Symbol
Min
Typ
Max
Unit
Operating
current
current
While Scanning
I
OP
350
400
mA
While in Standby
I
PRE
45
50
mA
While Charging
I
CHG1
350
400
mA
When OFF
I
off
100
150
μA
Battery
specifications
specifications
Voltage
V
BAT
2.75
3.7
4.2
V
Rated capacity
350
355
-
mAh
Charging current
I
CHG2
160
mA
Charging time
T
chg
-
-
2.5
hour
Scans when fully charged *1
Operating time
-
-
1500
20
-
-
-
-
Times
Hours
Scans when fully charged *2
Operating time
-
-
2500
35
-
-
-
-
Times
Hours
Startup time (from deep sleep)
T
d
75
-
-
ms
Notes
*1 One scan of 1 second per minute, Bluetooth link active, data transmitted
immediately after the scan..
immediately after the scan..
*2 One scan of 1 second per minute, Bluetooth link not active.