• Where Outdoor units are configurable by software to Tx power
values other than those for which the product is certified, it is the
responsibility of the Professional Installer to restrict the Tx power to
the certified limits.
The RADWIN 6000 band 2 should be installed and operated with a
minimum distance of 243 cm (8 ft) between the radiator and any
person and RADWIN 6000 band 5 should be installed and operated
with a minimum distance of 142 cm (4.7 ft) between the radiator
and any person
minimum distance of 243 cm (8 ft) between the radiator and any
person and RADWIN 6000 band 5 should be installed and operated
with a minimum distance of 142 cm (4.7 ft) between the radiator
and any person
Warning
• This product was tested with special accessories - FTP CAT 5e
shielded cable with sealing gasket, 10 AWG grounding cable - which
must be used with the unit to insure compliance.
Canadian Emission Requirements for Indoor Units
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. ation
configuration, best results will be obtained using Universal regulation configuration.
configuration, best results will be obtained using Universal regulation configuration.
Safety Practices
Applicable requirements of National Electrical Code (NEC), NFPA 70; and the National
Electrical Safety Code, ANSI/IEEE C2, must be considered during installation.
Electrical Safety Code, ANSI/IEEE C2, must be considered during installation.
NOTES:
1. A Primary Protector is not required to protect the exposed wiring as long as the
exposed wiring length is limited to less than or equal to 140 feet, and instructions are
provided to avoid exposure of wiring to accidental contact with lightning and power
conductors in accordance with NEC Sections 725-54 (c) and 800-30.
exposed wiring length is limited to less than or equal to 140 feet, and instructions are
provided to avoid exposure of wiring to accidental contact with lightning and power
conductors in accordance with NEC Sections 725-54 (c) and 800-30.
In all other cases, an appropriate Listed Primary Protector must be provided. Refer to
Articles 800 and 810 of the NEC for details.
Articles 800 and 810 of the NEC for details.
2. For protection of ODU against direct lightning strikes, appropriate requirements of NFPA
780 should be considered in addition to NEC.
3. For Canada, appropriate requirements of the CEC 22.1 including Section 60 and
additional requirements of CAN/CSA-B72 must be considered as applicable.
additional requirements of CAN/CSA-B72 must be considered as applicable.